Inspection Detail
Inspection: 304662547 - Pride Packing Co
Inspection Information - Office: Dosh Yakima Service Location, Yakima, Wa
Site Address:
Pride Packing Co
501 Maires Road/.5 Miles E Of Maires Road
Sunnyside, WA 98944
Mailing Address:
560 N Lateral B Road, Wapato, WA 98951
Union Status: NonUnion
SIC:0723
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/04/2001
Emphasis:
Case Closed: 01/16/2002
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361033095 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $5,100 | $0 | $0 | $0 | $0 | $5,100 |
Current Penalty | $5,100 | $0 | $0 | $0 | $0 | $5,100 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 3070003001 | 11/27/2001 | 12/30/2001 | $1,800 | $1,800 | $0 | - | ||
2. | 01002 | Serious | 3071500603 | 11/27/2001 | 10/04/2001 | $3,300 | $3,300 | $0 | - |
Investigation Summary
An employee was picking up irrigation pipe in an orchard. As he was loading the pipe onto a trailer, a section of pipe tilted up and contacted overhead power lines. The employee was electrocuted.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, AGRICULTURE, ELECTROCUTED, E GI IA, IRRIGATION PIPE, E PTD, IRRIGATION EQUIPMENT, LOST CONTROL, E AG
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 304662547 | Fatality | Electric Shock | Occupation not reported |