Powered by GoogleTranslate

Inspection Detail

Inspection: 304639644 - Fisher Development Inc.

Inspection Information - Office: Cincinnati Area Office

 

Inspection Nr: 304639644
Report ID: 0522000
Date Opened: 08/06/2001

Site Address:
Fisher Development Inc.
7875 Montgomery Rd.
Cincinnati, OH 45236

Mailing Address:
1485 Bayshore Dr., San Francisco, CA 94124

Union Status: NonUnion

SIC:1542

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 08/23/2001

Emphasis: S:Construction

Case Closed: 10/29/2002


Related Activity
Type Activity Nr Safety Health
Accident 101960516
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $15,000 $0 $0 $0 $0 $15,000
Current Penalty $7,500 $0 $0 $0 $0 $7,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100134 D01 III 08/24/2001 09/13/2001 $2,500 $5,000 $0 09/17/2001 J - ALJ Decision  
2. 01002A Serious 19260055 A 08/24/2001 09/13/2001 $2,500 $5,000 $0 09/17/2001 R - Review Commission  
3. 01002B Serious 19260055 B 08/24/2001 10/12/2001 $0 $0 $0 09/17/2001 R - Review Commission  
4. 01003 Serious 19101200 H01 08/24/2001 09/13/2001 $2,500 $5,000 $0 09/17/2001 R - Review Commission  

Investigation Summary

Investigation Nr: 837906
Event: 08/06/2001
Seven Employees Overcome By Carbon Monoxide

At approximately 6:30 a.m. on August 6, 2001, employees began to operate a 65-horsepower concrete cutting saw inside a room located on the lower level of a shopping mall being renovated in preparation for a new store to move in. The saw contained both gasoline and propane as available fuels. The operator stated that he was running the concrete saw in the propane mode. Engineering controls were not in use and air was not being moved into or out of the room being renovated. Catalytic converters and carbon monoxide monitor-alarms were not attached to this saw. Monitoring of airborne levels of carbon monoxide was not performed. Approximately 37 employees were taken to a hospital with symptoms of carbon monoxide poisoning. The narrative does not mention the extent of the injuries of thirty of these employees. Seven construction workers were transported to a hyperbaric oxygen chamber for further treatment. These seven employees were hospitalized and released the next day.

Keywords: ASPHYXIATED, AIR MONITORING, ALARM, AIR CONTAMINATION, PROPANE, GASOLINE, CARBON MONOXIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 304639644 Hospitalized injury Asphyxia Supervisors; plumbers, pipefitters & steamfitters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close