Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 304318173 - Oddee Smith Construction Inc.

Inspection Information - Office: Jackson

Nr: 304318173Report ID: 0419400Open Date: 03/10/2003

Oddee Smith Construction Inc.
Friendship Road 100 Yards Off Hwy. 44
Mccomb, MS 39648
Union Status: NonUnion
SIC: 1611/Highway and Street Construction, Except Elevated Highways
NAICS: 237310/ Highway, Street, and Bridge Construction
Mailing: Po Box 1407, Brookhaven, MS 39602

Inspection Type:Accident
Scope:Complete Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:04/09/2003
Emphasis: S:Construction FatalitiesClose Case:11/10/2003

Related Activity:TypeIDSafetyHealth
 Accident101363182    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $15,600 $0 $0 $0 $0 $15,600
Current Penalty $9,500 $0 $0 $0 $0 $9,500
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 19260021 B02 04/18/2003 04/24/2003 $2,000 $4,000 $0 I - Informal Settlement
  2. 01002 Serious 19260550 A04 04/19/2003 04/25/2003 $500 $2,000 $0 I - Informal Settlement
  3. 01003 Serious 19260550 A15 I 04/18/2003 04/24/2003 $4,000 $5,600 $0 I - Informal Settlement
  4. 01004 Serious 19260550 A15 IV 04/18/2003 04/24/2003 $3,000 $4,000 $0 I - Informal Settlement

Accident Investigation Summary
Summary Nr: 201361938Event: 03/10/2003Employee Electrocuted When Crane Line Contacts Power Line
On March 10, 2003, Employee #1 and coworkers were working for a company that was making bridge repairs. Mats constructed of treated timbers were stored underneath the 13,200-kilovolt phase-to-phase, 7,620 phase-to-neutral, three-phase power lines. The phases were 32 ft above ground and parallel to the county road. A crane was parked in the road, 20 ft from the roadside phase. One coworker was standing on the timber mats, holding a leg of a 20 ft wire rope sling which was placed on the hook of the load line. Employee #1, who was standing on the ground, was pulling the sling to get more slack. in the process, the crane load line contacted the overhead line. The coworker on the mat was not injured, but Employee #1 was electrocuted. The burned spots on the crane cable were located approximately 15 ft above the hook.
Keywords: clearance, overhead power line, repair, crane boom, work rules, electrocuted, struck against, construction, sling
Inspection Degree Nature Occupation
1 304318173 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.