Powered by GoogleTranslate

Inspection Detail

Inspection: 304264948 - Terry'S Electric, Inc.

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 304264948
Report ID: 0420600
Date Opened: 03/08/2001

Site Address:
Terry'S Electric, Inc.
Cason Rd & Coronet Rd
Plant City, FL 33564

Mailing Address:
600 N. Thacker Ave, Ste A, Kissimmee, FL 34741

Union Status: NonUnion

SIC:1731

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/23/2001

Emphasis: L:Flcare, L:Ohpwrlne, S:Construction, S:Construction Fatalities

Case Closed: 03/22/2002


Related Activity
Type Activity Nr Safety Health
Accident 102329620
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $7,000 $70,000 $0 $0 $0 $77,000
Current Penalty $7,000 $0 $0 $7,000 $0 $14,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Other 19260416 A01 08/01/2001 08/06/2001 $7,000 $7,000 $0 08/23/2001 F - Formal Settlement  
2. 01001B Other 19260550 A05 I 08/01/2001 08/06/2001 $0 $0 $0 08/23/2001 F - Formal Settlement  
3. 02001 Serious 19260021 B02 08/01/2001 09/06/2001 $7,000 $70,000 $0 08/23/2001 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202311403
Event: 03/07/2001
Electric Shock - Contact with Overhead Line thru Light Pole

A local utility company hired an electrical contractor to install new streetlighting at the corner of a hazardous intersection. The job required installing one of the streetlights parallel to an existing 13.2-kilovolt (phase-to-phase) overhead power line. The ground worker installed the streetlighting hardware and supply cable on the pole, placed a synthetic nylon sling with a choker hitch around the pole, and attached the sling to the load line of a derrick truck. When the derrick lifted the pole to an upright position, the derrick's tilt-pole plumber arms grasped the shaft of the pole. The operator of the derrick truck swung the load around and began to set the pole in a 1.8-meter-deep hole. The ground worker was securing the cargo straps to the pole trailer as the derrick operator was setting the pole. When the butt end of the pole contacted the bottom of the hole, the pole spun the streetlight into the overhead line. The ground worker ran to the pole to try to prevent it from contacting the overhead line. He was electrocuted when he touched the supply cable on the pole. He had entry and exit wounds on his right hand and right heel.

Keywords: DERRICK TRUCK, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, STREETLIGHTING, E PTD, ELEC UTILITY WORK, UTILITY POLE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 304264948 Fatality Electric Shock Electrical power installers and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close