Powered by GoogleTranslate

Inspection Detail

Inspection: 304032410 - American Pool Management

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 304032410
Report ID: 0352450
Date Opened: 12/08/2000

Site Address:
American Pool Management
611 Park Avenue
Baltimore, MD 21201

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:7997

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/08/2000

Emphasis:

Case Closed: 02/09/2001


Related Activity
Type Activity Nr Safety Health
Accident 100967652
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $3,600 $0 $0 $0 $0 $3,600
Current Penalty $1,800 $0 $0 $0 $0 $1,800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 50104 A 12/08/2000 12/09/2000 $1,800 $3,600 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 170831622
Event: 06/11/2000
Employee's leg injured in pump house explosion

Employee #1, a 19-year-old lifeguard, went into the pump house of rooftop swimming pool that had a closed cold water cleaning system. The pump house smelled strongly of chlorine and she saw hot water leaking from the hair lint filter onto the floor. She shut off the water pump and left to call the office. She returned to the pump house to shut off the entire system when the 40 lb PVC piping containing water and chlorine exploded. Employee #1 sustained broken bones in her right leg and the loss of upward flexibility in her right foot. Chlorine tablets had been added to the hair and lint filter the night before the explosion because of a broken feeder on the automatic chlorinator. Employee #1 was not certified as a pool operator or manager.

Keywords: AIR PRESSURE, FRACTURE, WORK RULES, CHLORINE, EXPLOSION, POOL, CHEMICAL REACTION, STRUCK BY, MECH MALFUNCTION, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 304032410 Hospitalized injury Fracture Guards and police, excluding public service
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.