Powered by GoogleTranslate

Inspection Detail

Inspection: 303989826 - Midwest Communication Towers, Llc

Inspection Information - Office: Jacksonville Area Office

 

Inspection Nr: 303989826
Report ID: 0419700
Date Opened: 08/21/2002

Site Address:
Midwest Communication Towers, Llc
Wogk-Fm Radio Tower
Anthony, FL 32617

Mailing Address:
16545 Smith Road, Salineville, OH 43945

Union Status: NonUnion

SIC:7389

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 10/31/2002

Emphasis:

Case Closed: 04/07/2003


Related Activity
Type Activity Nr Safety Health
Accident 101352557
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $1 $0 $0 $0 $0 $1
Current Penalty $1 $0 $0 $0 $0 $1
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 12/13/2002 04/03/2003 $1 $1 $0 P - Petition to Mod Abatement  

Investigation Summary

Investigation Nr: 201351806
Event: 08/21/2002
Employee Is Killed in Fall Down Tower Guy

On August 21, 2002, Employee #1 was part of a crew engaged in maintenance on a 1,265 ft tall communication tower. He was suspended from a guy cable by a hook and pulley assembly greasing the cables. He was wearing a body belt with a seat strap that was secured to the hook and pulley assembly by a single lanyard. There was also a 2 ft long chain connected to the body belt that could be used to secure the belt to the hook and pulley assembly. His movement up and down the guy cable was controlled by a 0.375-in. wire rope hoist line that ended in an eye with a shackle connected to the hook and pulley assembly. The hoist line ran from a 44,000 pound drum hoist mounted on a Ford 700 truck, through a 4-in. block that was rigged to the base of the tower, up the tower to a 2-in. block that was connected to the tower at the working elevation, and then to the hook and pulley assembly. Employee #1 was first lowered from the working level to near the ground, and then slowly pulled upwards as he greased the guy cable, which was at a 53 degree angle. When he reached the top portion of the guy cable, the crew would relocate the equipment to do the next guy cable. A rigger/spotter was positioned on the tower at the working level to watch Employee #1, and to communicate by radio to the winch operator located by the truck. Employee #1 was suspended from the guy cable just a few feet from the tower. The rigger/spotter heard a snap and then saw Employee #1 begin to travel down the guy cable. Employee #1, who was still attached to the hook and pulley assembly, rapidly traveled 586 ft down the cable until he struck the base of the guy cables. The base was a ground connection point for three different cables which were attached vertically, one over the other. Employee #1 was on the middle guy cable. He suffered massive blunt impact injuries, including multiple lacerations and fractures, and died. Subsequent investigation determined that the hoist line had become disconnected from the hook and pulley assembly. This assembly was damaged from the collision and it was not known what caused the separation. The rigger/spotter did not see how the connection to the hoist line was made, and the shackle may have been connected to a hook on the assembly that did not have a safety latch. The shackle may also have been connected to the assembly itself which could be opened. It was normally locked shut by a locking pin held in place by a cotter pin. The assembly was found open on the ground, but this may have been caused by the impact.

Keywords: ATTACHMENT HOOK, FRACTURE, SAFETY LATCH, COMMUNICATION TOWER, UNSECURED, GUY, FALL, FALL PROTECTION, TOWER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 303989826 Fatality Cut/Laceration Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close