Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 303939391 - Yamaha Motor Manufacturing Corporation Of America

Inspection Information - Office: Atlanta West

Nr: 303939391Report ID: 0418200Open Date: 06/03/2002

Yamaha Motor Manufacturing Corporation Of America
1000 Ga Highway 34 East
Newnan, GA 30265
Union Status: NonUnion
SIC: 3799/Transportation Equipment, Not Elsewhere Classified

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:07/03/2002
Close Case:08/21/2003

Related Activity:TypeIDSafetyHealth
 Accident100201458    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 2 1 3
Initial Penalty $18,900 $63,000 $0 $0 $0 $81,900
Current Penalty $11,025 $0 $0 $0 $56,700 $67,725
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001A Serious 19100147 C04 IIB 11/19/2002 02/21/2003 $4,725 $6,300 $0 12/11/2002 F - Formal Settlement
  2. 01001B Serious 19100147 C06 I 11/19/2002 02/21/2003 $0 $0 $0 12/11/2002 F - Formal Settlement
  3. 01001C Other 19100147 C04 II 11/19/2002 01/08/2003 $0 $0 $0 12/11/2002 F - Formal Settlement
  4. 01002A Serious 19100332 B01 11/19/2002 02/21/2003 $6,300 $6,300 $0 12/11/2002 F - Formal Settlement
  5. 01002B Serious 19100333 A 11/19/2002 02/21/2003 $0 $0 $0 12/11/2002 F - Formal Settlement
  6. 01002C Serious 19100333 A01 11/19/2002 11/22/2002 $0 $0 $0 12/11/2002 F - Formal Settlement
Deleted 7. 01002D Serious 19100333 A02 11/19/2002 02/21/2003 $0 $0 $0 12/11/2002 F - Formal Settlement
Deleted 8. 01002E Serious 19100333 C02 11/19/2002 11/22/2002 $0 $0 $0 12/11/2002 F - Formal Settlement
  9. 01002F Serious 19100333 B02 I 11/19/2002 01/08/2003 $0 $0 $0 12/11/2002 Q - National Office Adjustment
Deleted 10. 01003 Serious 19100333 B02 I 11/19/2002 01/08/2003 $6,300 $6,300 $0 12/11/2002 F - Formal Settlement
Deleted 11. 01004 Serious 19100335 A02 I 11/19/2002 11/22/2002 $6,300 $6,300 $0 12/11/2002 F - Formal Settlement
  12. 02001 Unclass 19100303 F 11/19/2002 04/04/2003 $56,700 $63,000 $0 12/11/2002 F - Formal Settlement

Accident Investigation Summary
Summary Nr: 200201820Event: 06/01/2002Employee Is Electrocuted Pulling Hot Wire With Pliers
Employee #1 was in a room standing in a Sky Jack scissor lift waiting to receive fish tape through the end of a 0.75 in. metal raceway (which came to a junction box). A coworker was in an adjacent room pushing the fish tape towards Employee #1 through the metal raceway up in the ceiling. The coworker was standing in a Handy Herman lifting device. Employee #1 reached up to the junction box with a pair of uninsulated pliers to pull the fish tape. Instead, he pulled a hot wire with the pliers. The pliers apparently broke through the insulation around the hot wire, and Employee #1 received an electric shock of 277 volts. He was electrocuted. The circuit was 480 volts phase-to-phase. Power had not been disconnected in either room.
Keywords: elec insulation, electric switch, work rules, electrocuted, electric conductor, electric shock, electrical box, hand tool
Inspection Degree Nature Occupation
1 303939391 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.