Powered by GoogleTranslate

Inspection Detail

Inspection: 303766869 - Romech

Inspection Information - Office: Iowa 0751910

 

Inspection Nr: 303766869
Report ID: 0751910
Date Opened: 11/20/2001

Site Address:
Romech
2700 N. Broadway
Red Oak, IA 51566

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3499

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/16/2002

Planning Guide: Safety-Manufacturing

Emphasis: S:Fatality/Catastrophe, S:General Industry

Case Closed: 03/19/2002


Related Activity
Type Activity Nr Safety Health
Inspection 303766851
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $9,500 $0 $0 $0 $0 $9,500
Current Penalty $5,000 $0 $0 $0 $0 $5,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 C04 II 02/07/2002 03/27/2002 $1,250 $2,500 $0 I - Informal Settlement  
2. 01002 Serious 19100147 F02 I 02/07/2002 03/27/2002 $1,250 $2,000 $0 I - Informal Settlement  
3. 01003 Serious 19100212 A03 II 02/07/2002 02/12/2002 $1,250 $2,500 $0 I - Informal Settlement  
4. 01004 Serious 19100304 D01 I 02/07/2002 03/27/2002 $1,250 $2,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200524593
Event: 08/17/2001
Employee amputates tip of left thumb

At approximately 11:15 a.m. on August 17, 2001, Employee #1 was working with the GMT 315 Shim test machine. During the testing process, he manually clamped the (60 Recliner Mechanism) into the fixture of the machine's frame. He then placed his left hand on the left front side of the frame. His left thumb was extended into the point of operation. Next, he activated the air cylinder through pressing the top front air control lever with his right hand. As he did so, the air cylinder placing a horizontal force on the part to be tested. The cylinder travels approximately 3 in. to the left. During the travel of the cylinder, Employee #1 left thumb was pinched between the cylinders face and the frame of the left side of the machine. Employee #1 reacted by pulling his left hand away from the machine, resulting in the tip of the left thumb being amputated. This was the second time that he had operated the one-person operating machine.

Keywords: ROTATING PARTS, AMPUTATED, THUMB, TEST EQUIPMENT, PRESS CYLINDER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 303766869 Non Hospitalized injury Amputation Industrial engineers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close