Powered by GoogleTranslate

Inspection Detail

Inspection: 303685374 - Cudd Pressure Control, Inc.

Inspection Information - Office: Corpus Christi Area Office

 

Inspection Nr: 303685374
Report ID: 0626000
Date Opened: 08/03/2001

Site Address:
Cudd Pressure Control, Inc.
1420 Hwy 44 East
Robstown, TX 78380

Mailing Address:
Po Box 10405, Corpus Christi, TX 78460

Union Status: NonUnion

SIC:1389

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/09/2001

Emphasis: L:Oilgas

Case Closed: 07/09/2002


Related Activity
Type Activity Nr Safety Health
Accident 100211176
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 1 1 2
Initial Penalty $7,650 $0 $0 $0 $0 $7,650
Current Penalty $2,125 $0 $0 $850 $0 $2,975
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 10/26/2001 06/01/2002 $2,125 $2,125 $0 P - Petition to Mod Abatement  
2. 01002 Other 19100023 C01 10/26/2001 11/01/2001 $850 $1,700 $0 I - Informal Settlement  
3. 01003 Serious 19100132 C 10/26/2001 11/23/2001 $0 $1,700 $0 I - Informal Settlement Citation has been deleted.
4. 01004 Serious 19100212 A01 10/26/2001 11/23/2001 $0 $2,125 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 200210938
Event: 08/03/2001
Employee killed in fall from top of spool of coiled tubing

On August 3, 2001, Employee #1 was preparing a spool on a coil tubing unit for change out and replacement with another spool containing different diameter pipe or tubing. A coil tubing unit is a mobile unit that carries 15,000 to 20,000 feet of pipe coiled around a spool for deployment into existing oil or gas wells. Employee #1 was standing on top of the spool, about 12 feet above ground level. As he cut the tubing to free it from the injector, the approximately 10-foot in diameter spool he was standing on began to turn slowly. The spool's hydraulic system was engaged, the brake was not set, and the spool was not secured or chained. In addition, Employee #1 had tied his safety lanyard off to the rim of the spool. Tied at the waist and unable to unhook his lanyard, Employee #1 was subsequently pulled through a 10-inch gap between the spool and its frame. The lanyard broke away and the spool then made several revolutions before another operator could climb up into the control room to stop the spool. The incident resulted in a fatal injury to Employee #1, who was asphyxiated.

Keywords: ASPHYXIATED, CAUGHT BETWEEN, FALL, OIL WELL SERVICING, PIPE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 303685374 Fatality Asphyxia Winding and twisting machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close