Powered by GoogleTranslate

Inspection Detail

Inspection: 303614978 - Dixie Component Systems Inc

Inspection Information - Office: Utah Division Of Occupational Safety And Health

 

Inspection Nr: 303614978
Report ID: 0854910
Date Opened: 03/01/2001

Site Address:
Dixie Component Systems Inc
353 N 3050 E
St George, UT 84770

Mailing Address:
353 North 3050 East, St. George, UT 84770

Union Status: NonUnion

SIC:2439

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/05/2001

Planning Guide: Safety-Manufacturing

Emphasis: S:Manufacturing

Case Closed: 06/08/2001


Related Activity
Type Activity Nr Safety Health
Accident 362653446
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $1,050 $0 $0 $0 $0 $1,050
Current Penalty $1,050 $0 $0 $0 $0 $1,050
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 10005 C07 04/19/2001 04/25/2001 $1,050 $1,050 $0 -  
2. 02001 Other 10008 C01 04/19/2001 04/25/2001 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 171060627
Event: 02/28/2001
Employee crushed between gantry and table

Employee #1 was building roof trusses on a table located adjacent to a MiTek Roof Glider roof truss roller gantry. The gantry had just rolled over a truss being constructed and had stopped in the "parking zone". The gantry operator then reversed the gantry because it was covering a truss located on the manual production table, so the truss could be removed. After the gantry initially stopped in the "parking zone", Employee #1 crawled on the ground between two tables located on the side of the gantry where the gantry had just passed, apparently to retrieve some plates on the ground to use in constructing trusses. The gantry operator was unaware that Employee #1 had crawled in between the tables; when he reversed the gantry, Employee #1 was crushed between the outer gantry frame and a metal post of one of the tables. The operator realized something was in the pathway of the gantry but was unable to see Employee #1 until he exited the operator control platform and examined the area between the tables. Employee #1 was conscious and breathing for a short time (1-2 minutes) then became unconscious. Employee #1 entered cardiac arrest, and two employees immediately began CPR and continued until paramedics arrived a few minutes later. Employee #1 was pronounced dead in the hospital emergency room.

Keywords: TRUSS, ROOF, GANTRY CRANE, CRUSHED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 303614978 Fatality Other Miscellaneous woodworking machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.