Powered by GoogleTranslate

Inspection Detail

Inspection: 303363576 - Mountain States Construction Co

Inspection Information - Office: Dosh Yakima Service Location, Yakima, Wa

 

Inspection Nr: 303363576
Report ID: 1055350
Date Opened: 02/07/2000

Site Address:
Mountain States Construction Co
420 Loretta St
Sunnyside, WA 98944

Mailing Address:
Po Box 918, Sunnyside, WA 98944

Union Status: NonUnion

SIC:1542

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/23/2000

Emphasis: L:Wasafety

Case Closed: 06/16/2000


Related Activity
Type Activity Nr Safety Health
Accident 361217813
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $1,350 $0 $0 $0 $0 $1,350
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 1550042801 E 01 03/20/2000 02/23/2000 $1,350 $1,350 $0 04/04/2000 Y - State Decision Citation has been deleted.

Investigation Summary

Investigation Nr: 171038953
Event: 02/07/2000
ELECTRIC SHOCK - DIRECT CONTACT WITH OVERHEAD LINE

Two employees were measuring a building. One employee was in a scissor lift, holding a tape measure. The other employee was on a wall of the building, apparently was holding the other end of the tape measure. The employee in the lift raised it to roof level and contacted a 72-kilovolt overhead power line. He was electrocuted. The other employee received an electric shock and sustained burns on his hands and knees where he was kneeling. He then fell 8.5 meters to the ground. He was hospitalized for his injuries.

Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, MEASURING DEVICE, ELECTROCUTED, ELECTRIC SHOCK, FALL, FALL PROTECTION, AERIAL LIFT, E GI IB

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 303363576 Fatality Electric Shock Occupation not reported
2 303363576 Hospitalized injury Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.