Inspection: 303211304 - Hawker Power Systems, Inc.

Inspection Information - Office: Kansas City Area Office

 

Inspection Nr: 303211304
Report ID: 0728500
Date Opened: 01/08/2001

Site Address:
Hawker Power Systems, Inc.
4500 Progress Place
Springfield, MO 65803

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3692

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/09/2001

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 04/09/2001


Related Activity
Type Activity Nr Safety Health
Accident 100001288

Investigation Summary

Investigation Nr: 200001154
Event: 01/05/2001
Employee struck by falling load is killed

At approximately 1:30 p.m. on January 5, 2001, a sheet metal worker and a crane operator were in the process of moving a fan unit for a dust collection system from its holding area to a concrete pad. The fan unit had been rigged with three nylon web slings 2 inches wide and 10 ft long attached to the crane hook. As the load was being raised and moved, approximately 5 to 6 ft., Employee #1 attempted to cross over from one side of the raised fan unit to get to the other side of the fan unit. Employee #1 was between the existing dust collection system and the raised load when two nylon slings broke. He was struck by the load and was killed.

Keywords: SUSPENDED LOAD, STRUCK BY, SLING, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 303211304 Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.