Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 303189757 - Southern Grouts And Mortars, Inc

Inspection Information - Office: Ft. Lauderdale

Nr: 303189757Report ID: 0418800Open Date: 04/11/2001

Southern Grouts And Mortars, Inc
1502 Sw 2nd Place
Pompano Beach, FL 33069
Union Status: NonUnion
SIC: 3281/Cut Stone and Stone Products

Inspection Type:Accident
Scope:Complete Advanced Notice:Y
Ownership:Private
Safety/Health:Safety Close Conference:07/06/2001
Close Case:12/14/2001

Related Activity:TypeIDSafetyHealth
 Accident100673987    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $12,600 $0 $0 $0 $0 $12,600
Current Penalty $8,820 $0 $0 $0 $0 $8,820
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 19100028 A01 07/09/2001 07/13/2001 $4,410 $6,300 $0 07/26/2001 J - ALJ Decision
  2. 01002 Serious 19100147 C01 07/09/2001 07/12/2001 $4,410 $6,300 $0 07/26/2001 J - ALJ Decision

Accident Investigation Summary
Summary Nr: 200673275Event: 04/11/2001Electric Shock - Direct Contact With Energized Conductor
Three employees were replacing the packer on a bag-packing machine. They had turned off the machine, but had not opened the circuit breaker supplying the wiring to the machine. One of the employees fell against and broke the conduit containing the energized conductors on the supply side of the machine's power switch. The employee contacted the conductors and was electrocuted. His two coworkers received electric shocks when they tried to move him away from the energized conductors. The coworkers were treated at a hospital and released.
Keywords: e gi iv, electrical, conduit, electrocuted, lockout, electric conductor, electric shock, fall
Inspection Degree Nature Occupation
1 303189757 Non Hospitalized injury Electric Shock Occupation not reported
2 303189757 Non Hospitalized injury Electric Shock Occupation not reported
3 303189757 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.