Inspection Detail
Inspection: 303172027 - Pacific Cast Technologies Inc
Inspection Information - Office: Eugene
Site Address:
Pacific Cast Technologies Inc
150 Queen Ave Sw
Albany, OR 97321
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3369
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 07/28/2000
Planning Guide: Health-Manufacturing
Emphasis:
Case Closed: 10/31/2001
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 1 | 4 | |||
Current Violations | 1 | 1 | ||||
Initial Penalty | $1,300 | $0 | $0 | $0 | $0 | $1,300 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 701076006 | 08/01/2000 | 10/15/2000 | $0 | $500 | $0 | 08/21/2000 | D - Govt Dismissed | Citation has been deleted. |
2. | 01002 | Serious | 701076001 B A | 08/01/2000 | 08/18/2000 | $0 | $300 | $0 | 08/21/2000 | D - Govt Dismissed | Citation has been deleted. |
3. | 01003 | Serious | 701076001 A | 08/01/2000 | 08/18/2000 | $0 | $500 | $0 | 08/21/2000 | D - Govt Dismissed | Citation has been deleted. |
4. | 02004 | Other | 19100157 C04 | 08/01/2000 | 02/18/2000 | $0 | $0 | $0 | 08/21/2000 | D - Govt Dismissed |
Investigation Summary
Employee #1 was grinding a titanium alloy part in the grinding shack when a coworker smelled a pungent odor. After the coworker left the shack to investigate the odor, Employee #1 noticed a glow in the dust hog, or exhaust ventilation unit, so he left the grinding shack to turn off the ventilation. Another coworker was turning off the ventilation, so Employee #1 returned to the shack and, finding the door to the dust hog open, removed the smoldering filter from the dust hog. As he did this, the filter dropped to the floor. Employee #1 was kneeling to pick it up when coworkers sprayed the filter with a fire extinguisher. Employee #1 inhaled the smoke and/or the chemical material, and suffered respiratory distress. He was transported by the company environmental manager to Albany General Hospital, where he was held overnight.
Keywords: EXHAUST SYSTEM, VAPOR, METAL SHOP, FIRE, INHALATION, RESPIRATORY TRACT, CHEMICAL VAPOR, GRINDING ROOM, SMOKE INHALATION, CHEMICAL
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 303172027 | Hospitalized injury | Other | Occupation not reported |