Powered by GoogleTranslate

Inspection Detail

Inspection: 302800305 - Business Electronics Soldering Technologies, Inc.

Inspection Information - Office: Chicago North Area Office

 

Inspection Nr: 302800305
Report ID: 0524200
Date Opened: 07/26/1999

Site Address:
Business Electronics Soldering Technologies, Inc.
3603 Edison Place
Rolling Meadows, IL 60008

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3672

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/26/1999

Emphasis:

Case Closed: 10/06/1999


Related Activity
Type Activity Nr Safety Health
Accident 101260784

Investigation Summary

Investigation Nr: 201260569
Event: 07/23/1999
Employee Suffers Heart Attack at Work Station

On July 23, 1999, Employee #1 was working at a bench removing and replacing components on printed circuit boards. The components are held in place with solder which Employee #1 had to melt to remove the defective component. After removing the defective component Employee #1 installed the replacement component and soldered it in place. Employee #1 was bonded to the table with a wrist strap. An autopsy revealed the cause of death to be coronary arteriosclerosis.

Keywords: HEART, SHOCK, ELECTRICAL, HEART ATTACK, ELECTRONIC CONTROL, WORK STATION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 302800305 Fatality Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.