Powered by GoogleTranslate

Inspection Detail

Inspection: 302738182 - F. R. P. Industries, Inc. (Baja Cruisers)

Inspection Information - Office: Jacksonville Area Office

 

Inspection Nr: 302738182
Report ID: 0419700
Date Opened: 06/02/2000

Site Address:
F. R. P. Industries, Inc. (Baja Cruisers)
Hwy 51 N
Mayo, FL 32066

Mailing Address:
P. O. Box 478, Mayo, FL 32066

Union Status: NonUnion

SIC:3732

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 08/22/2000

Emphasis:

Case Closed: 10/18/2000


Related Activity
Type Activity Nr Safety Health
Accident 101351088
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 5 9
Current Violations 4 5 9
Initial Penalty $6,000 $0 $0 $2,500 $0 $8,500
Current Penalty $4,163 $0 $0 $1,735 $0 $5,898
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 09/26/2000 10/30/2000 $694 $1,000 $0 I - Informal Settlement  
2. 01002 Serious 19100106 E06 I 09/26/2000 09/29/2000 $1,735 $2,500 $0 I - Informal Settlement  
3. 01003A Serious 19100213 H03 09/26/2000 09/29/2000 $867 $1,250 $0 I - Informal Settlement  
4. 01003B Serious 19100213 H04 09/26/2000 09/29/2000 $0 $0 $0 -  
5. 01004 Serious 19100215 B09 09/26/2000 09/29/2000 $867 $1,250 $0 I - Informal Settlement  
6. 02001 Other 19040004 09/26/2000 10/10/2000 $0 $0 $0 -  
7. 02002 Other 19040008 09/26/2000 09/29/2000 $1,735 $2,500 $0 I - Informal Settlement  
8. 02003 Other 19100303 B02 09/26/2000 09/29/2000 $0 $0 $0 -  
9. 02004 Other 19100303 G01 09/26/2000 09/29/2000 $0 $0 $0 -  
10. 02005 Other 19100305 B01 09/26/2000 09/29/2000 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 201351244
Event: 05/31/2000
Three employees burned when acetone vapors ignite

Employees #1 through #3 were cleaning and detailing a boat that was in the last stage of manufacturing. Employees #1 and #2 were in the cabin of the boat, and Employee #3 was in the back cockpit; all were cleaning with acetone contained in quart-sized containers. When Employee #1 started up an electric vacuum cleaner, it apparently ignited the acetone vapors in the air of the cabin, resulting in a flash fire. All three employees sustained burns, for which they were hospitalized.

Keywords: BURN, VENTILATION, FLAMMABLE VAPORS, WORK RULES, CLEANING, FIRE, ACETONE, EXPLOSION, CLEANING FLUID

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 302738182 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 302738182 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 302738182 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.