Powered by GoogleTranslate

Inspection Detail

Inspection: 302733654 - Del Zotto Products Of Florida, Inc.

Inspection Information - Office: Jacksonville Area Office

 

Inspection Nr: 302733654
Report ID: 0419700
Date Opened: 10/05/1999

Site Address:
Del Zotto Products Of Florida, Inc.
4405 W Highway 40
Ocala, FL 34482

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3272

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/21/1999

Emphasis: S:Amputations

Case Closed: 02/14/2000


Related Activity
Type Activity Nr Safety Health
Accident 101350809
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 5 11
Current Violations 6 5 11
Initial Penalty $4,900 $0 $0 $0 $0 $4,900
Current Penalty $3,185 $0 $0 $0 $0 $3,185
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 11/30/1999 01/19/2000 $455 $700 $0 I - Informal Settlement  
2. 01002A Serious 19100243 C04 11/30/1999 12/08/1999 $455 $700 $0 I - Informal Settlement  
3. 01002B Serious 19100133 A01 11/30/1999 12/03/1999 $0 $0 $0 -  
4. 01003 Serious 19100136 A 11/30/1999 12/10/1999 $569 $875 $0 I - Informal Settlement  
5. 01004 Serious 19100212 A01 11/30/1999 12/03/1999 $569 $875 $0 I - Informal Settlement  
6. 01005 Serious 19100212 A03 II 11/30/1999 01/19/2000 $569 $875 $0 I - Informal Settlement  
7. 01006 Serious 19100305 B02 IIIG 11/30/1999 12/03/1999 $569 $875 $0 I - Informal Settlement  
8. 02001 Other 19100022 A01 11/30/1999 12/03/1999 $0 $0 $0 -  
9. 02002 Other 19100147 C04 I 11/30/1999 01/19/2000 $0 $0 $0 -  
10. 02003 Other 19100147 C07 I 11/30/1999 01/19/2000 $0 $0 $0 -  
11. 02004 Other 19100179 B05 11/30/1999 12/03/1999 $0 $0 $0 -  
12. 02005 Other 19100253 B04 I 11/30/1999 12/03/1999 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 201350816
Event: 10/05/1999
Employee is electrocuted

Employee #1, a welder in a steel fabrication shop, was going to weld on a steel form. He was using an overhead hoist to position the form and lowered the 5,500 pound steel form onto an electrical cord. The electrical cord supplied power to a Miller Millermatic 300 electric welder. The welding machine was off, but its cord was plugged into a 480-volt outlet. The steel form cut into the insulation of the cord, and the form became electrically energized. Employee #1 was electrocuted when he came into contact with the steel form and died.

Keywords: ELECTROCUTED, WELDER, HOIST, ELECTRIC CORD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 302733654 Fatality Electric Shock Welders and cutters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.