Powered by GoogleTranslate

Inspection Detail

Inspection: 302417928 - Shakespeare Co. - Monofilament Division

Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation

 

Inspection Nr: 302417928
Report ID: 0454510
Date Opened: 08/30/1999

Site Address:
Shakespeare Co. - Monofilament Division
6111 Shakespeare Rd
Columbia, SC 29204

Mailing Address:
4900 South Eastern Ave., Ste. 200, Los Angelos, CA 90040

Union Status: NonUnion

SIC:2221

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/26/1999

Emphasis:

Case Closed: 01/27/2000


Related Activity
Type Activity Nr Safety Health
Accident 100370485
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3 6
Current Violations 3 3 6
Initial Penalty $5,625 $0 $0 $0 $0 $5,625
Current Penalty $2,250 $0 $0 $0 $0 $2,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100038 A03 I 11/12/1999 11/17/1999 $750 $1,875 $0 I - Informal Settlement  
2. 01002 Serious 19100038 A05 11/12/1999 12/16/1999 $750 $1,875 $0 I - Informal Settlement  
3. 01003 Serious 19101200 H01 11/12/1999 12/16/1999 $750 $1,875 $0 I - Informal Settlement  
4. 02001 Other 19100134 C01 11/12/1999 12/16/1999 $0 $0 $0 I - Informal Settlement  
5. 02002 Other 19100134 E01 11/12/1999 12/16/1999 $0 $0 $0 I - Informal Settlement  
6. 02003 Other 19100134 K03 11/12/1999 12/16/1999 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 170572242
Event: 08/28/1999
Thirteen employees exposed to chemical vapors

On August 28, 1999, a chemical release occurred from flash tank of pressure vessel #3. Employees #1 through #13 and 25 coworkers were overcome by the vapors and taken to area hospitals, where they were treated and released. The vapors eventually reached electrical components and ignited a flash fire. The release was caused by an unapproved gasket being installed in a manway.

Keywords: VAPOR, GASKET, WORK RULES, FIRE, INHALATION, SEAL, CHEMICAL VAPOR, OVEREXPOSURE, MECH MALFUNCTION, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 302417928 Non Hospitalized injury Other Extruding and forming machine operators
2 302417928 Non Hospitalized injury Other Machinery maintenance occupations
3 302417928 Non Hospitalized injury Other Occupation not reported
4 302417928 Non Hospitalized injury Other Extruding and forming machine operators
5 302417928 Non Hospitalized injury Other Machine operators, not specified
6 302417928 Non Hospitalized injury Other Extruding and forming machine operators
7 302417928 Non Hospitalized injury Other Extruding and forming machine operators
8 302417928 Non Hospitalized injury Other Production inspectors, checkers and examiners
9 302417928 Non Hospitalized injury Other Extruding and forming machine operators
10 302417928 Non Hospitalized injury Other Extruding and forming machine operators
11 302417928 Non Hospitalized injury Other Extruding and forming machine operators
12 302417928 Non Hospitalized injury Other Extruding and forming machine operators
13 302417928 Non Hospitalized injury Other Extruding and forming machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close