Powered by GoogleTranslate

Inspection Detail

Inspection: 301878054 - Process Manufacturing Co., Inc.

Inspection Information - Office: Oklahoma City Area Office

 

Inspection Nr: 301878054
Report ID: 0627700
Date Opened: 08/05/1998

Site Address:
Process Manufacturing Co., Inc.
5800 W 68th Street
Tulsa, OK 74131

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3533

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/06/1998

Emphasis:

Case Closed: 03/04/1999


Related Activity
Type Activity Nr Safety Health
Accident 100641059
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $6,250 $0 $0 $0 $0 $6,250
Current Penalty $6,250 $0 $0 $0 $0 $6,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100146 C01 11/23/1998 12/26/1998 $1,250 $1,250 $0 -  
2. 01002 Serious 19100147 C04I 11/23/1998 12/11/1998 $2,500 $2,500 $0 -  
3. 01003 Serious 19100147 C07I 11/23/1998 12/11/1998 $2,500 $2,500 $0 -  
4. 02001 Other 19101200 H 11/23/1998 12/26/1998 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 200640951
Event: 07/29/1998
Employee killed when carbon dioxide cylinder discharges

Employee #1 and a coworker were salvaging a truck-mounted turbine fracturizing pumping unit. They had removed various components including the pump and, in preparation for removing the turbine engine, were dismantling the engine's integral charged carbon dioxide fire suppression system. Employee #1 had disconnected the carbon dioxide cylinder hose from the manifold hose and from both ends of the system's manual discharge cable housing. He then asked the coworker to hand him a set of wire cutters. As he was cutting the discharge cable, he pulled on it, causing the cylinder to discharge. The hose snapped violently under the cylinder's 2,500 lb pressure, and Employee #1's throat was struck either by the end of the hose or by the high-pressure discharge stream. His larynx and trachea were severely injured, cutting off air to his lungs. The coworker, who had started to escape when the incident began, returned to aid Employee #1. He received immediate first aid from coworkers, but he was without oxygen for several minutes. Employee #1 was transported by ambulance to a local hospital, where he was kept alive for 24 hours to facilitate organ donations. The cause of the accident was lack of lockout/tagout procedures to render the carbon dioxide cylinder safe, and the lack of recognition of the hazard by the employees.

Keywords: THROAT, DISMANTLING, CYLINDER, WORK RULES, LOCKOUT, HIGH PRESSURE, STRUCK BY, FLYING OBJECT, UNTRAINED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301878054 Fatality Cut/Laceration Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close