Inspection: 301732004 - Cutrale Citrus Juices Usa, Inc.

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 301732004
Report ID: 0420600
Date Opened: 08/29/1997

Site Address:
Cutrale Citrus Juices Usa, Inc.
602 Mckean St.
Auburndale, FL 33823

Mailing Address:
P.O. Box 157, Auburndale, FL 33823

Union Status: Union

SIC:2033

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/05/1997

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 01/20/1998


Related Activity
Type Activity Nr Safety Health
Accident 361089246
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $6,375 $0 $0 $0 $0 $6,375
Current Penalty $6,375 $0 $0 $0 $0 $6,375
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100023 C01 11/20/1997 01/07/1998 $1,875 $1,875 $0 -  
2. 01002 Serious 19100333 C03 11/20/1997 11/25/1997 $4,500 $4,500 $0 -  

Investigation Summary

Investigation Nr: 202287827
Event: 08/29/1997
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU LOAD LINE

An employee of a citrus food company climbed onto the roof of the northwest corner of a building to reach a catwalk adjacent to an auger screw conveyor line. He was going to replace a section of the screw conveyor. The citrus food company had hired a contractor to use a telescopic mobile crane to lift the section of the screw conveyor that was being replaced. The crane operator positioned the crane and lowered the load line. The employee on the roof grabbed the hook on the load line and pulled it towards him. The crane operator extended the boom towards the employee on the roof to facilitate hooking the load. The load line contacted a 13.3-kilovolt overhead power line. The employee on the roof received an electric shock and went into cardiac arrest. His coworkers and emergency services personnel administered cardio-pulmonary resuscitation. The injured employee was transported to a hospital, where he later died of electrocution.

Keywords: OVERHEAD POWER LINE, ROOF, ELECTRICAL, CPR, ELECTROCUTED, E GI IA, LOAD LINE, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301732004 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.