Powered by GoogleTranslate

Inspection Detail

Inspection: 301428397 - Certified Construction Inc

Inspection Information - Office: Hi-E-Honolulu

 

Inspection Nr: 301428397
Report ID: 0951510
Date Opened: 05/17/1999

Site Address:
Certified Construction Inc
Kuntz Ave & Mcchord St Bldg #1843
Hickam Afb, HI 96853

Mailing Address:
1009 Ulupono St, Honolulu, HI 96819

Union Status: NonUnion

SIC:1761

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/30/1999

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 12/01/1999


Related Activity
Type Activity Nr Safety Health
Accident 101950210
Complaint 201939766 Yes

Investigation Summary

Investigation Nr: 201941176
Event: 05/14/1999
Two employees injured when crane contacted high voltage line

Employee #1 was going to pick up a pallet load of roof cap sheet rolls from the ground and place the load onto the third floor roof. He was using a National Crane, Model Number 875B, serial number 19198, mounted on a Ford truck, license number 855-TJB. Employee #1 raised his 85-foot high crane boom and extended it over a 40-foot high power tree. Employee #1 then lowered the crane's hook and main hoist line over and through some obstructing tree branches and between two 11,500 kilovolt high-voltage power lines. Employee #1 lowered the crane's hook about 5 feet directly above the pallet of roof caps. The power lines were about two feet apart and about 25-feet high above the ground. Employee #1 got off his crane truck and walked to this pallet load. Employee #2 then met with Employee #1 to assist Employee #1 to rig up the pallet load of roof caps. Employee #1 realized that the load would be unstable to lift. Employee #1 then decided that he was going to use the crane's material box that was on the back of his truck to lift the roof caps up to the roof. While Employee #1 and Employee #2 were walking back to the crane, Employee #2 noticed a small blue or green fire on the right front outrigger between the right front outrigger base and the wood block. Employee #2 told Employee #1 about the outrigger on fire. Employee #2 then said that he saw Employee #1 get shocked when Employee #1 touched the front right outrigger. Employee #1 fell to the ground. Employee #1 told Employee #2 to turn off the crane. Employee #2 went to the driver's side of the crane and jumped onto the truck and also was shocked. Employee #1 received burns on the bottom of his right hand in the "narrow area" with three separate quarter inch diameter electrical burns between his wrist and baby finger "like when you are going to Karate chop someone." Employee #1 also received an exit wound on the bottom of his right foot the size of a fifty-cent coin. Employee #1 was hospitalized and was able to return to work a month later. Employee #2 complained of chest pains and was hospitalized and was able to return back to work about a week later. According to the witnesses, the crane's hoist line had swayed back and forth between the high voltage lines.

Keywords: BURN, ELECTROCUTED, ELECTRIC SHOCK, PALLET, HAND, CRANE, FOOT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301428397 Hospitalized injury Electric Shock Crane and tower operators
2 301428397 Hospitalized injury Electric Shock Roofers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close