Powered by GoogleTranslate

Inspection Detail

Inspection: 301336855 - Miller Casting Inc.

Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 301336855
Report ID: 0950644
Date Opened: 11/07/2005

Site Address:
Miller Casting Inc.
2503 Pacific Park Dr
Whittier, CA 90601

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3364

NAICS: 331522/Nonferrous (except Aluminum) Die-Casting Foundries


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/05/2006

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/21/2008


Related Activity
Type Activity Nr Safety Health
Accident 362599557
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 3 3
Initial Penalty $22,500 $0 $0 $6,500 $0 $29,000
Current Penalty $0 $0 $0 $5,750 $0 $5,750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 04/05/2006 04/22/2006 $3,000 $5,000 $0 05/26/2006 F - Formal Settlement  
2. 01002 Other 3314 G02 A 04/05/2006 04/22/2006 $0 $750 $0 05/26/2006 F - Formal Settlement Citation has been deleted.
3. 01003 Other 3314 J04 04/05/2006 04/22/2006 $750 $750 $0 05/26/2006 F - Formal Settlement  
4. 02001 Other 3314 C 04/05/2006 04/15/2006 $2,000 $22,500 $0 05/26/2006 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201800323
Event: 10/08/2005
Employee Amputated Finger in Adbrasive Blast Machine

At approximately 6:40 a.m. on October 8, 2005, Employee #1, amputated a finger while operating a Golf 3 cube barrel blast machine. The Employee was using the barrel blast machine to remove residual ceramic coatings on products. This particular machine had a problem of continually getting clogged with the sand and other metal debris. Employee #1 opened the abrasive access door of the Golf 3 cube barrel blast machine located on the lower front of the cabinet to check if there were any problems. The Employee found that a piece of metal wire in the Elevator Separator of Abrasive Recycling System was jammed into the machine and disrupting the blasting operation. The employee pulled on the metal wire to try to free it, but unexpectedly this wire pulled his right hand into the Elevator Separator. Employee #1 right hand contacted the moving components of the elevator separator which caused an amputation of a right little finger to first digit with bone loss and fractures to the second and third right fingers as well as a deep laceration on the extensor tendon of right index finger.

Keywords: FRACTURE, ROTATING PARTS, AMPUTATED, ABRASIVE BLASTING, FINGER, WORK RULES, MACHINE OPERATOR, LOCKOUT, CAUGHT BETWEEN, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301336855 Hospitalized injury Amputation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close