Powered by GoogleTranslate

Inspection Detail

Inspection: 301330833 - Rapid Rack Industries, Inc.

Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 301330833
Report ID: 0950644
Date Opened: 10/29/2003

Site Address:
Rapid Rack Industries, Inc.
14421 Bonelli Street
Industry, CA 91744

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2542

NAICS: 337127/Institutional Furniture Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/06/2004

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 09/13/2010


Related Activity
Type Activity Nr Safety Health
Accident 362590416
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $18,000 $0 $0 $370 $0 $18,370
Current Penalty $2,700 $0 $0 $300 $0 $3,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 01/06/2004 01/26/2004 $150 $185 $0 02/02/2004 F - Formal Settlement  
2. 01002 Other 23400023 01/06/2004 02/09/2004 $150 $185 $0 02/02/2004 F - Formal Settlement  
3. 02001 Serious 4214 A 01/06/2004 01/26/2004 $2,700 $18,000 $0 02/02/2004 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201797446
Event: 10/23/2003
Employee injures thumb while operating punch press

At approximately 7:00 a.m. on October 23, 2003, Employee #1 was operating a press brake manufactured by Durma Corporation, Model Number HAP 30120, Serial Number 7042024057. He was bending 36-inch-long by 2-inch-wide sections of sheet metal during the manufacture of metal storage racks. The employee was placing the raw stock in the dies using his fingers when his hand became stuck in the upper die, causing the amputation of the tip of his left thumb. He was hospitalized with his injury. The investigation revealed that although the press was equipped with a two-hand trip capability and a presence sensing device, the employer stated that it was suspected that the light-curtain-type guard may have been out of adjustment.

Keywords: AMPUTATED, SHEET METAL, PRESS BRAKE, THUMB, POINT OF OPERATION, LIGHT CURTAIN, PRESS OPERATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301330833 Hospitalized injury Amputation Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close