Inspection Detail
Inspection: 301325551 - Gto Packing, Inc
Inspection Information - Office: Fremont District Office
Site Address:
Gto Packing, Inc
32357 Mccoy Road
Soledad, CA 93960
Mailing Address:
149 Nestles Road, Ste A, Soledad, CA 93960
Union Status: NonUnion
SIC:0761
NAICS: 115115/Farm Labor Contractors and Crew Leaders
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/20/2006
Emphasis: S:Agriculture (Aship)
Case Closed: 05/10/2006
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 102452265 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $25,000 | $0 | $0 | $0 | $0 | $25,000 |
Current Penalty | $25,000 | $0 | $0 | $0 | $0 | $25,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 3455 | 04/13/2006 | 04/18/2006 | $25,000 | $25,000 | $0 | - |
Investigation Summary
At approximately 11:21 a.m. on November 16, 2005, Employee #1 was cleaning dirt from the inside of a metal irrigation pipe. When Employee #1 raised the pipe in an attempt to force the dirt out, the pipe made contact with an overhead power line. Employee #1 was electrocuted.
Keywords: SHOCK, OVERHEAD POWER LINE, CLEANING, ELECTROCUTED, ELECTRIC SHOCK, PIPE, IRRIGATION EQUIPMENT
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 301325551 | Fatality | Electric Shock | Occupation not reported |