Powered by GoogleTranslate

Inspection Detail

Inspection: 301309795 - Cor-Pro Systems, Inc.

Inspection Information - Office: Houston North Area Office

 

Inspection Nr: 301309795
Report ID: 0626600
Date Opened: 10/03/1997

Site Address:
Cor-Pro Systems, Inc.
10545 Fischer Road
Houston, TX 77041

Mailing Address:
P.O. Box 114785, Houston, TX 77240

Union Status: NonUnion

SIC:3479

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 10/03/1997

Emphasis:

Case Closed: 05/13/1998


Related Activity
Type Activity Nr Safety Health
Accident 360902035
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 2 8
Current Violations 6 2 8
Initial Penalty $15,000 $0 $0 $0 $0 $15,000
Current Penalty $15,000 $0 $0 $0 $0 $15,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100107 C02 11/19/1997 04/16/1998 $2,500 $2,500 $0 P - Petition to Mod Abatement  
2. 01002 Serious 19100107 C06 11/19/1997 11/28/1997 $2,500 $2,500 $0 I - Informal Settlement  
3. 01003 Serious 19100107 C08 11/19/1997 11/24/1997 $2,500 $2,500 $0 I - Informal Settlement  
4. 01004 Serious 19100304 F04 11/19/1997 11/24/1997 $2,500 $2,500 $0 I - Informal Settlement  
5. 01005 Serious 19100305 G02 II 11/19/1997 11/24/1997 $2,500 $2,500 $0 I - Informal Settlement  
6. 01006 Serious 19100332 B01 11/19/1997 01/15/1998 $2,500 $2,500 $0 I - Informal Settlement  
7. 02001 Other 19100134 B01 11/19/1997 11/24/1997 $0 $0 $0 I - Informal Settlement  
8. 02002 Other 19101200 E01 11/19/1997 01/15/1998 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 201760519
Event: 10/03/1997
Explosion

Employee #1 was assigned to spray paint the inside of two 2.3-kiloliter marine portable tanks. The spray paint was flammable. When the employee requested a light to illuminate the inside of the tanks, his supervisor gave him a small battery-operated flashlight. The employee used the flashlight when he painted the first tank. He ran out of paint for the second tank and asked his helper to mix some more. His helper had apparently connected a Leen and Associates portable Halogen light (Serial No. EY64HDH) that was not approved for use in Class I locations. An explosion occurred, burning Employee #1. He died of his injuries.

Keywords: BURN, E GI V, ELECTRICAL, FLAMMABLE VAPORS, SPRAY PAINTING, PAINT, EXPLOSION, EQUIPMENT APPROVAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301309795 Fatality Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.