Powered by GoogleTranslate

Inspection Detail

Inspection: 301236980 - Lacamas Laboratories Inc

Inspection Information - Office: Or-E-Portland - Safety 1 1054111

 

Inspection Nr: 301236980
Report ID: 1054192
Date Opened: 04/11/1997

Site Address:
Lacamas Laboratories Inc
3625 N Suttle Rd
Portland, OR 97217

Mailing Address:
Po Box 17659, Portland, OR 97217

Union Status: NonUnion

SIC:2833

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 04/17/1997

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 01/28/1998


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3 6
Current Violations 3 3 6
Initial Penalty $750 $0 $0 $0 $0 $750
Current Penalty $750 $0 $0 $0 $0 $750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 701076001 D 05/08/1997 04/11/1997 $300 $300 $0 -  
2. 01002 Serious 19100146 C02 05/08/1997 04/11/1997 $180 $180 $0 -  
3. 01003 Serious 19100146 D03 I 05/08/1997 06/23/1997 $270 $270 $0 -  
4. 02004 Other 19100146 G04 05/08/1997 06/23/1997 $0 $0 $0 P - Petition to Mod Abatement  
5. 02005 Other 702016102 A 05/08/1997 06/08/1997 $0 $0 $0 -  
6. 02006 Other 701076506 A B 05/08/1997 04/11/1997 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 510362
Event: 04/17/1997
Employee burned when methanol fumes ignite

Employee #1 was cleaning a reactor used to prepare 1,1-dimethyl-3-pyrodinyl carbonate in which a nickel catalyst was used. He opened the manway to rinse the reactor with methanol, exposing some of the nickel to the air. The nickel sparked and ignited the methanol fumes. Employee #1 sustained second- and third-degree burns in the resulting fire. The employer was cited for numerous violations, including inadequate training and confined space regulations.

Keywords: BURN, METHYL ALCOHOL, REACTOR, FLAMMABLE VAPORS, WORK RULES, CLEANING, FIRE, CHEMICAL REACTION, SPARK, COMBUSTIBLE DUST

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301236980 Hospitalized injury Burn/Scald(Heat) Chemical technicians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.