Powered by GoogleTranslate

Inspection Detail

Inspection: 301215117 - Green Valley Pump Inc

Inspection Information - Office: Or-E-Salem 1054100

 

Inspection Nr: 301215117
Report ID: 1054118
Date Opened: 06/02/1997

Site Address:
Green Valley Pump Inc
6991 Rapp Ln
Talent, OR 97540

Mailing Address:
609 S Pacific Hwy, Talent, OR 97540

Union Status: NonUnion

SIC:5074

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/28/1997

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 07/08/1998


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $8,750 $0 $0 $0 $0 $8,750
Current Penalty $3,500 $0 $0 $0 $0 $3,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 702032401 09/05/1997 09/10/1997 $1,000 $2,500 $0 09/12/1997 L - State Settlement  
2. 01001B Serious 702032201 09/05/1997 09/10/1997 $0 $0 $0 09/12/1997 L - State Settlement  
3. 01002 Serious 19100132 D01 09/05/1997 09/10/1997 $1,000 $1,250 $0 09/12/1997 L - State Settlement  
4. 01003 Serious 701076001 A 09/05/1997 09/10/1997 $1,500 $5,000 $0 09/12/1997 L - State Settlement  
5. 02004 Other 19101200 E01 09/05/1997 10/06/1997 $0 $0 $0 09/12/1997 L - State Settlement  

Investigation Summary

Investigation Nr: 201610011
Event: 05/30/1997
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Two employees were pulling a pump from a well at a residence. One employee was working at the well, and the other employee was working from a boom truck. The employees had parked the boom truck on a secondary road, and the well was located 7.3 meters from the truck. An overhead power line ran between the truck and the well (3.0 meters from the truck and 4.3 meters from the well). The employee operating the truck set it up to position the boom under the power line. The employees pulled two 3.0-meter lengths of pipe successfully. However, the next section of pipe was 6.4 meters long. They used the winch to pull the pipe as high as they could, but the pipe did not clear the well. The employee who was operating the boom repositioned it over the power line and fully extended the telescoping boom to about 14.6 meters. He then began to lower the load line. The load line did not line up, so the operator positioned the boom within about a meter of the power line. Current arced to the boom. The employee who was working at the well was holding on to the load line, guiding it to the hole. He received an electric shock. The boom truck operator moved the boom away from the power line, and the employee on the ground was thrown back about 4.6 meters. He was hospitalized for his injuries.

Keywords: BOOM TRUCK, OVERHEAD POWER LINE, ELECTRICAL, BOOM, E GI IA, ELECTRIC SHOCK, TRUCK BOOM

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301215117 Hospitalized injury Electric Shock Plumbers, pipefitters and steamfitters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close