Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 301131629 - Safeway Inc. - San Leandro Milk Plant

Inspection Information - Office: Ca Oakland

Nr: 301131629Report ID: 0950614Open Date: 01/21/2002

Safeway Inc. - San Leandro Milk Plant
2000 Adams Ave
San Leandro, CA 94578
Union Status: Union
SIC: 2026/Fluid Milk

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:07/17/2002
Planning Guide: Safety-Manufacturing Close Case:06/22/2006

Related Activity:TypeIDSafetyHealth
 Accident361482599    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 3 3 6
Current Violations 1 4 5
Initial Penalty $66,735 $0 $0 $1,800 $0 $68,535
Current Penalty $25,000 $0 $0 $7,690 $0 $32,690
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Other 23400023 07/17/2002 07/22/2002 $315 $315 $0 07/25/2002 F - Formal Settlement
  2. 01002 Other 3314 H 07/17/2002 08/04/2002 $0 $850 $0 07/25/2002 F - Formal Settlement
  3. 01003 Other 5162 E 07/17/2002 08/04/2002 $375 $635 $0 07/25/2002 F - Formal Settlement
  4. 02001 Serious 3314 A 07/17/2002 07/27/2002 $25,000 $25,000 $0 07/25/2002 F - Formal Settlement
Deleted 5. 03001 Serious 3314 C 07/17/2002 07/27/2002 $0 $5,735 $0 07/25/2002 F - Formal Settlement
  6. 04001 Other 3314 F 07/17/2002 07/27/2002 $7,000 $36,000 $0 07/25/2002 F - Formal Settlement

Accident Investigation Summary
Summary Nr: 201502937Event: 01/21/2002Employee Killed When Crushed By Conveyor
On January 21, 2002, Employee #1, a maintenance employee, attempted to adjust the slack on the "CC" conveyor chain. Employee #1 did not deenergize, lockout, or tagout the 120-volt control circuits, the hydraulic systems, and the 480-volt conveyor supply circuits. The employer did not develop, implement and utilize an energy control procedural steps for shutting down, isolating, blocking, and securing machines or equipment to control hazardous energy during maintenance and adjusting operations. Employee #1 was lying on and reaching through the energized conveyor "AH" to adjust the "CC" conveyor chain take-up. Employee #1 triggered the micro switch on the stop gate that opened the hydraulic racing valve serving the stack pushers, which engaged the stack pusher that fatally injured Employee #1.
Keywords: chain, maintenance, amputated, lockout, crushed, conveyor
Inspection Degree Nature Occupation
1 301131629 Fatality Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close