Powered by GoogleTranslate

Inspection Detail

Inspection: 301125571 - Uss-Posco Industries, Llc

Inspection Information - Office: American Canyon District Office

 

Inspection Nr: 301125571
Report ID: 0950622
Date Opened: 08/16/2006

Site Address:
Uss-Posco Industries, Llc
900 Loveridge Rd.
Pittsburg, CA 94565

Mailing Address:
P.O. Box 471, Pittsburg, CA 94565

Union Status: Union

SIC:3316

NAICS: 331221/Rolled Steel Shape Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/16/2006

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 04/15/2010


Related Activity
Type Activity Nr Safety Health
Accident 101483592
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $18,000 $0 $0 $0 $0 $18,000
Current Penalty $7,000 $0 $0 $0 $0 $7,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 3212 A05 09/21/2006 09/20/2006 $7,000 $18,000 $0 10/13/2006 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201488772
Event: 04/01/2006
Employee Burns Leg in Hot Water after Stepping in Hole

On April 1, 2006, Employee #1 and a coworker were assigned to change out a sump pump located in the Continuous Annealing Line basement. The old sump pump had been removed and the new sump pump was on a cart on top of the grated metal floor. At approximately 2:38 a.m., while walking around the cart, Employee #1 stepped through a hole in the floor grating and his right leg went through the hole into hot water to a point above the knee. The water beneath the floor is approximately 185 degrees Fahrenheit. Employee #1 suffered third-degree burns to the right leg and lesser burns to the right arm where he was splashed by hot water. Employee #1 was hospitalized.

Keywords: BURN, FLOOR HOLE, GRATING, ARM, HOT WATER, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301125571 Hospitalized injury Burn/Scald(Heat) Electricians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close