Powered by GoogleTranslate

Inspection Detail

Inspection: 301033445 - Wireless One

Inspection Information - Office: Jackson Area Office

 

Inspection Nr: 301033445
Report ID: 0419400
Date Opened: 09/25/1997

Site Address:
Wireless One
3390 Bacon Rd.
Scobey, MS 38953

Mailing Address:
179 Hwy 6 E, Oxford, MS 38655

Union Status: NonUnion

SIC:4841

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 09/26/1997

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 01/05/1998


Related Activity
Type Activity Nr Safety Health
Accident 101360543
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $975 $0 $0 $1,000 $0 $1,975
Current Penalty $750 $0 $0 $750 $0 $1,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100268 C03 11/12/1997 12/31/1997 $750 $975 $0 I - Informal Settlement  
2. 01001B Serious 19100268 C 11/12/1997 12/31/1997 $0 $0 $0 -  
3. 02001 Other 19040008 11/12/1997 11/17/1997 $750 $1,000 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 201360393
Event: 09/24/1997
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU ANTENNA

An employee working alone was proof testing a television signal at a residence. A 1440-volt overhead power line that was 8.2 meters above the ground was located nearby. The proofing equipment consisted of a 10.7-meter-long, telescoping fiberglass pole, a 12.2-meter-long coaxial cable, and a meter to measure the signal received by an antenna installed on the end of the fiberglass pole. The employee raised the antenna with fiberglass pole. He had the meter hanging by a strap wrapped around his neck. The antenna contacted the power line, and the employee was electrocuted. He was not discovered until 3 hours after the accident.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, ANTENNA, E GI IB

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301033445 Fatality Electric Shock Electronic repairers, communica. & indus. equip.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.