Powered by GoogleTranslate

Inspection Detail

Inspection: 301031019 - Charles Williams Contractor

Inspection Information - Office: Jackson Area Office

 

Inspection Nr: 301031019
Report ID: 0419400
Date Opened: 05/01/1997

Site Address:
Charles Williams Contractor
2020 Moss Avenue
Jackson, MS 39212

Mailing Address:
150 Cleo Clark Road, Canton, MS 39046

Union Status: NonUnion

SIC:1761

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/01/1997

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 06/16/1998


Related Activity
Type Activity Nr Safety Health
Accident 101360386
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $4,500 $0 $0 $0 $0 $4,500
Current Penalty $4,500 $0 $0 $0 $0 $4,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19261053 B08 06/02/1997 06/06/1997 $750 $750 $0 -  
2. 01002 Serious 19261053 B12 06/02/1997 06/12/1997 $1,500 $1,500 $0 -  
3. 01003 Serious 19261053 B16 06/02/1997 06/06/1997 $1,500 $1,500 $0 -  
4. 01004 Serious 19261060 A01 III 06/02/1997 07/18/1997 $750 $750 $0 -  

Investigation Summary

Investigation Nr: 201360278
Event: 04/30/1997
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU LADDER

Two employees were taking down an aluminum extension ladder from the side of a church. A 7200-volt overhead power line was located 3 meters from the church. Because the sections of the ladder would not retract easily and because the ladder did not have a rope or other device to move the ladder sections, the employees had to lay the ladder on the ground and force the sections of the ladder together or apart. As the employees were lowering the extended ladder, it contacted the power line. One employee was electrocuted. The other employee received an electric shock and suffered severe burns. She was hospitalized for her injuries.

Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, LADDER, METAL LADDER, ELECTRIC SHOCK, E GI IB

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301031019 Fatality Electric Shock Occupation not reported
2 301031019 Hospitalized injury Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close