Inspection: 301004958 - Phoenix Metal Fabricating Inc.

Inspection Information - Office: Buffalo Area Office

 

Inspection Nr: 301004958
Report ID: 0213600
Date Opened: 12/21/1998

Site Address:
Phoenix Metal Fabricating Inc.
245 Harrison Street
Jamestown, NY 14701

Mailing Address:
P. O. Box 1030, Jamestown, NY 14702

Union Status: NonUnion

SIC:3444

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/21/1999

Emphasis: L:Metforg, S:Amputations

Case Closed: 05/17/2000


Related Activity
Type Activity Nr Safety Health
Referral 201331212 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $0 $44,000 $0 $0 $0 $44,000
Current Penalty $0 $0 $0 $0 $30,000 $30,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Unclass 19100212 A01 04/22/1999 04/26/1999 $30,000 $44,000 $0 05/12/1999 J - ALJ Decision  
2. 02001 Other 19100147 C04 I 04/22/1999 04/27/1999 $0 $0 $0 J - ALJ Decision  

Investigation Summary

Investigation Nr: 201330164
Event: 12/11/1998
Employee's hands amputated when caught by press brake

On December 11, 1998, Employee #1 reached into the point of operation of a foot pedal-operated hydraulic press brake to make adjustments to the work stops (fingers). While reaching, his foot was on the foot pedal and it activated the brake, bringing the top ram down onto his arms, almost severing both hands. The employee was transported to the hospital where his hands were amputated and reattached. The light curtain used to guard the point of operation had been bypassed by the use of black electrical tape. Management was aware of the condition and permitted it to exist because one particular part could not be done with the light curtain working properly.

Keywords: AMPUTATED, PRESS BRAKE, WORK RULES, CAUGHT BETWEEN, POINT OF OPERATION, FOOT-POWERED PRESS, LIGHT CURTAIN, PRESS OPERATOR, HAND, UNGUARDED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301004958 Hospitalized injury Amputation Fabricating machine operators, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close