Powered by GoogleTranslate

Inspection Detail

Inspection: 300958477 - Ccc Group, Inc.

Inspection Information - Office: Birmingham Area Office

 

Inspection Nr: 300958477
Report ID: 0418300
Date Opened: 04/01/1997

Site Address:
Ccc Group, Inc.
A B C Coke, 900 Railroad Ave.
Tarrant, AL 35217

Mailing Address:
1420 Hildegarge St., Birmingham, AL 35215

Union Status: NonUnion

SIC:1629

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 04/01/1997

Emphasis:

Case Closed: 04/02/1997


Related Activity
Type Activity Nr Safety Health
Accident 101270122

Investigation Summary

Investigation Nr: 201270345
Event: 03/31/1997
Four employees burned in gas main explosion

Employees #1 through #4 were at a plant working on a gas main when the line exploded. All four sustained burns, for which they were hospitalized.

Keywords: FLAMMABLE VAPORS, EXPLOSION, BURN, MAINTENANCE, VAPOR, FLAMMABLE LIQUID, CONSTRUCTION, GAS

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300958477 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 300958477 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 300958477 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close