Powered by GoogleTranslate

Inspection Detail

Inspection: 300872074 - Cast-Rite Corporation

Inspection Information - Office: Los Angeles District Office

 

Inspection Nr: 300872074
Report ID: 0950641
Date Opened: 08/06/2009

Site Address:
Cast-Rite Corporation
515 E. Airline Way
Gardena, CA 90248

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3363

NAICS: 331521/Aluminum Die-Casting Foundries


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/14/2010

Emphasis:

Case Closed: 11/06/2010


Related Activity
Type Activity Nr Safety Health
Accident 102576972
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 1
Initial Penalty $18,000 $0 $0 $1,120 $0 $19,120
Current Penalty $0 $0 $0 $750 $0 $750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3314 H 01/14/2010 02/03/2010 $0 $560 $0 02/11/2010 F - Formal Settlement Citation has been deleted.
2. 01002 Other 3314 G01 01/14/2010 02/03/2010 $0 $560 $0 02/11/2010 F - Formal Settlement Citation has been deleted.
3. 02001 Other 3314 C 01/14/2010 02/03/2010 $750 $18,000 $0 02/11/2010 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202541033
Event: 07/21/2009
Employee's Fingers Are Amputated in Die-Casting Machine

At approximately 4:45 p.m. on July 21, 2009, Employee #1 was a machine operator at a manufacturer of metal die cast parts for various industries. The slide carrier was manually lifted up in order to reinstall the slide face of die machine Number 18. The machine activated the hydraulic cylinder connected to the slide carrier, and it lowered immediately. Employee #1's fingers were caught between the slide face and the mold. He suffered an amputation to first knuckle of his right middle and ring fingers but was not hospitalized. The machine had not been deenergized or locked and tagged out.

Keywords: AMPUTATED, FINGER, MACHINE OPERATOR, HYDRAULIC CYLINDER, LOCKOUT, CAUGHT BETWEEN, DIE CASTING MACHINE, MOLD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300872074 Non Hospitalized injury Amputation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close