Powered by GoogleTranslate

Inspection Detail

Inspection: 300843745 - Sheedy Drayage Co.

Inspection Information - Office: Foster City District Office

 

Inspection Nr: 300843745
Report ID: 0950613
Date Opened: 12/28/2005

Site Address:
Sheedy Drayage Co.
55 West 3rd Street
San Mateo, CA 94402

Mailing Address:
1215 Michigan Street Po Box 77004, San Francisco, CA 94107

Union Status: Union

SIC:8741

NAICS: 236220/Commercial and Institutional Building Construction


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/26/2006

Emphasis:

Case Closed: 07/26/2012


Related Activity
Type Activity Nr Safety Health
Accident 101128031
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2 4
Current Violations 1 3 4
Initial Penalty $36,000 $0 $0 $980 $0 $36,980
Current Penalty $4,500 $0 $0 $1,730 $0 $6,230
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 23050004 06/26/2006 07/30/2006 $420 $420 $0 07/20/2006 F - Formal Settlement  
2. 01002 Other 23400021 06/26/2006 07/30/2006 $560 $560 $0 07/20/2006 F - Formal Settlement  
3. 02001 Other 16040024 B04 06/26/2006 07/30/2006 $750 $18,000 $0 07/20/2006 F - Formal Settlement  
4. 03001 Serious 16040024 H03 06/26/2006 07/30/2006 $4,500 $18,000 $0 07/20/2006 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201125960
Event: 12/27/2005
Employee's Arm Is Amputated in Fall from Personnel Hoist

At approximately 4:50 p.m. on December 27, 2005, Employee #1 and a coworker were traveling up in an Alimak 4000 construction personnel hoist, when the elevator began to emit loud screaming noises. Employee #1 attempted to stop the hoist by operating the emergency switch but it did not work. He then began moving other levers and still the elevator car continued moving upward at a high rate of speed. For unknown reasons, he opened the elevator door, reached his arm out the door, and fell 30 feet to the ground. His right arm was amputated and he was hospitalized. The elevator continued moving upward until it crashed into the top of the mast.

Keywords: AMPUTATED, CONSTRUCTION, EQUIPMENT FAILURE, HOIST, FALL, ARM, MECH MALFUNCTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300843745 Hospitalized injury Amputation Supervisors, material moving equipment operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.