Powered by GoogleTranslate

Inspection Detail

Inspection: 300829843 - Lightway Industries

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 300829843
Report ID: 0950643
Date Opened: 05/27/2005

Site Address:
Lightway Industries
28435 Industry Dr.
Valencia, CA 91355

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3646

NAICS: 335122/ Commercial, Industrial, and Institutional Electric Lighting Fixture Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/27/2005

Emphasis:

Case Closed: 08/26/2008


Related Activity
Type Activity Nr Safety Health
Accident 362528499
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $14,400 $0 $0 $275 $0 $14,675
Current Penalty $5,400 $0 $0 $275 $0 $5,675
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 10/27/2005 11/13/2005 $275 $275 $0 01/31/2006 F - Formal Settlement  
2. 02001 Serious 4214 A 10/27/2005 11/13/2005 $5,400 $14,400 $0 01/31/2006 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201119815
Event: 04/28/2005
Employee Amputates Finger Operating Hydraulic Brake Press

At approximately 1:55 p.m. on April 28, 2005, Employee #1, a temporary employee for a lighting fixtures manufacturer, was performing the duties of a press operator. He had been performing this duty for three days. As Employee #1 was operating an Amanda hydraulic brake press, which was controlled through a foot pedal, to bend a strip of metal in half for a lighting fixture, he hand fed the parts without the aid of an extension tool. The press cycled as Employee #1's right hand was in the point of operation, amputating the tip of his right index finger. First aid was initially provided to Employee #1 at his place of employment and he was then transported to medical facility, where an orthopedic surgeon reattached the tip of his right index finger. The accident investigation revealed that neither Employee #1 nor his Supervisor were aware of or trained in the requirement to use an extension tool to add and remove parts from the die.

Keywords: AMPUTATED, PRESS BRAKE, FINGER, GUARD, WORK RULES, CAUGHT BETWEEN, INEXPERIENCE, PRESS OPERATOR, UNTRAINED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300829843 Non Hospitalized injury Amputation Pressing machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.