Inspection Detail
Inspection: 300828100 - Raytheon
Inspection Information - Office: Van Nuys District Office
Site Address:
Raytheon
75 Coromar Blvd.
Goleta, CA 93117
Mailing Address:
6800 Cortona Dr., Goleta, CA 93117
Union Status: NonUnion
SIC:3812
NAICS: 334511/ Search, Detection, Navigation, Guidance, Aeronautical, and Nautical System and Instrument Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/31/2005
Emphasis:
Case Closed: 01/31/2005
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362524878 |
Investigation Summary
Employee #1 was transporting an 800-lb liquid oxygen cylinder using a specialized hand cart. The cart has a hook that attaches to the top of the cylinders during transport. However, the cylinder that was delivered was larger and heavier than normal. Employee #1 placed the oversized cylinder on the cart and attached the hook. Due to the size and weight of the cylinder the hook could not hold the cylinder in place and snapped off causing the cylinder to fall of the cart. Employee #1 tried to jump out of the way and somehow got his right third and fourth finger caught between the cart and the cylinder. Employee #1 sustained crushing injuries to his right third and fourth fingers. Employee #1 was taken to the hospital where he was treated for his injuries. Doctors were required to shave off the bone in order to repair Employee #1's fingers. Employee #1 was not hospitalized.
Keywords: AMPUTATED, CYLINDER, FINGER, CAUGHT BETWEEN, CRUSHED, CART
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300828100 | Non Hospitalized injury | Amputation | Freight, stock and material handlers, n.e.c. |