Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 300792892 - Marriott Hotel

Inspection Information - Office: Ca San Diego

Nr: 300792892Report ID: 0950632Open Date: 02/05/2003

Marriott Hotel
333 W Harbor Dr
San Diego, CA 92101
Union Status: NonUnion
SIC: 7011/Hotels and Motels
NAICS: 532412/ Construction, Mining, and Forestry Machinery and Equipment Rental and Leasing

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:05/08/2003
Close Case:07/07/2009

Related Activity:TypeIDSafetyHealth
 Accident362071748    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $24,750 $0 $0 $185 $0 $24,935
Current Penalty $24,750 $0 $0 $185 $0 $24,935
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Other 3203 A 05/09/2003 06/14/2003 $185 $185 $0 W - Empr Withdrew
  2. 02001 Serious 3578 G 05/09/2003 05/14/2003 $3,375 $3,375 $0 W - Empr Withdrew
  3. 03001 Serious 4309 D 05/09/2003 05/14/2003 $3,375 $3,375 $0 06/09/2003 W - Empr Withdrew
  4. 04001 Serious 4300 A 05/09/2003 05/14/2003 $18,000 $18,000 $0 W - Empr Withdrew

Accident Investigation Summary
Summary Nr: 300792892Event: 12/30/2002Employee Injured When Wrist Amputated By Circular Saw Blade
At 3:15 p.m. on December 30, 2002, Employee #1 suffered an industrial accident. Employee #1 was utilizing a circular saw to trim the under side of hotel doors. The employer is in the hotel management business. Employee #1 was the person operating this saw and is a regular employee of this employer, not a contract employee. Employee #1 was working in the maintenance shop at the hotel at the time of this accident. Equipment involved was a circular panel saw manufactured by Safety Speed Cut. The saw was a Milwaukee 2.5 unit, Catalog Number 6410, Serial Number 771B400440092, a 120 Volt, 13 Amp saw unit. Employee #1 was utilizing the circular saw as a panel saw. Employee #1 had removed the guard that covered the blade. While operating the saw, Employee #1's left wrist came into contact with the unguarded blade. This resulted in the amputation of Employee #1's left wrist, and Employee #1 was hospitalized.
Keywords: amputated, carpenter, circular saw, blade, unguarded, wrist
Inspection Degree Nature Occupation
1 300792892 Hospitalized injury Amputation Supervisors; carpenters and related workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.