Powered by GoogleTranslate

Inspection Detail

Inspection: 300791746 - Ferro Electronic Materials

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 300791746
Report ID: 0950632
Date Opened: 10/04/2002

Site Address:
Ferro Electronic Materials
1395 Aspen Way
Vista, CA 92083

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3469

NAICS: 332116/Metal Stamping


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/26/2003

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 01/13/2009


Related Activity
Type Activity Nr Safety Health
Accident 362071367
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 1 3 4
Initial Penalty $18,000 $0 $0 $1,875 $0 $19,875
Current Penalty $18,000 $0 $0 $450 $0 $18,450
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 03/14/2003 04/16/2003 $300 $375 $0 I - Informal Settlement  
2. 01002 Other 3203 A 03/14/2003 04/16/2003 $0 $750 $0 I - Informal Settlement  
3. 01003 Other 5144 G 03/14/2003 04/16/2003 $150 $750 $0 I - Informal Settlement  
4. 02001 Serious 5549 A 03/14/2003 04/16/2003 $18,000 $18,000 $0 04/09/2003 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201065687
Event: 09/16/2002
Employee's Face and Arms Are Burned in Flash Fire

At approximately 8:15 a.m. on September 16, 2002, Employee #1, with Ferro Electronics, a manufacturer of specialty parts and materials for the electronics industry, was operating a ball mill. He was transferring flammable liquids from one container to another when a flash fire erupted. Employee #1 was hospitalized with first- and second-degree burns to his face and arms. The containers he was using did not have the proper bonding straps and he was not wearing the required personal protective equipment.

Keywords: BURN, PROTECTIVE CLOTHING, FLAMMABLE LIQUID, PPE, WORK RULES, FIRE, BONDING, CHEMICAL REACTION, ARM, FACE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300791746 Hospitalized injury Burn/Scald(Heat) Chemical technicians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.