Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Alert: Due to routine maintenance on the OSHA website, some pages may be temporarily unavailable.
To report an emergency, file a complaint with OSHA or ask a safety and health question, call 1-800-321-6742 (OSHA).

Inspection Detail

Inspection: 300791746 - Ferro Electronic Materials

Inspection Information - Office: Ca San Diego

Nr: 300791746Report ID: 0950632Open Date: 10/04/2002

Ferro Electronic Materials
1395 Aspen Way
Vista, CA 92083
Union Status: NonUnion
SIC: 3469/Metal Stampings, Not Elsewhere Classified
NAICS: 332116/Metal Stamping

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:02/26/2003
Planning Guide: Safety-Manufacturing Close Case:01/13/2009

Related Activity:TypeIDSafetyHealth
 Accident362071367    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 1 3 4
Initial Penalty $18,000 $0 $0 $1,875 $0 $19,875
Current Penalty $18,000 $0 $0 $450 $0 $18,450
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Other 342 A 03/14/2003 04/16/2003 $300 $375 $0 I - Informal Settlement
  2. 01002 Other 3203 A 03/14/2003 04/16/2003 $0 $750 $0 I - Informal Settlement
  3. 01003 Other 5144 G 03/14/2003 04/16/2003 $150 $750 $0 I - Informal Settlement
  4. 02001 Serious 5549 A 03/14/2003 04/16/2003 $18,000 $18,000 $0 04/09/2003 F - Formal Settlement

Accident Investigation Summary
Summary Nr: 201065687Event: 09/16/2002Employee'S Face And Arms Are Burned In Flash Fire
At approximately 8:15 a.m. on September 16, 2002, Employee #1, with Ferro Electronics, a manufacturer of specialty parts and materials for the electronics industry, was operating a ball mill. He was transferring flammable liquids from one container to another when a flash fire erupted. Employee #1 was hospitalized with first- and second-degree burns to his face and arms. The containers he was using did not have the proper bonding straps and he was not wearing the required personal protective equipment.
Keywords: burn, protective clothing, flammable liquid, ppe, work rules, fire, bonding, chemical reaction, arm, face
Inspection Degree Nature Occupation
1 300791746 Hospitalized injury Burn/Scald(Heat) Chemical technicians

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close