Inspection: 300788429 - Kiewit Pacific Co

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 300788429
Report ID: 0950632
Date Opened: 02/13/2002

Site Address:
Kiewit Pacific Co
19090 Via Ambiente Ste 400
Escondido, CA 92029

Mailing Address:
, , 00000

Union Status: Union

SIC:1623

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/16/2002

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 05/17/2002


Related Activity
Type Activity Nr Safety Health
Accident 362066946

Investigation Summary

Investigation Nr: 201064656
Event: 02/12/2002
Employee injured when conveyor system collapses

At approximately 5:50 a.m. on February 12, 2002, Employee #1 was operating a rotating conveyor system. The conveyor transports concrete to the construction site from a remote concrete production facility. He was in the operator's cab which was attached to the conveyor system. The conveyor system failed structurally and collapsed. Employee #1 fell approximately 20 ft. sustaining internal and head injuries and was hospitalized.

Keywords: HEAD, COLLAPSE, CONSTRUCTION, EQUIPMENT FAILURE, CONVEYOR, FALL, CONCRETE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300788429 Hospitalized injury Concussion Miscellaneous material moving equipment operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.