Site Address:
Ortiz Corporation
1566 Cable St
San Diego, CA 92107

Mailing Address:
788 Energy Way, Chula Vista, CA 91911

Union Status: NonUnion

SIC:1711

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/27/2001

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 03/12/2002


Related Activity
Type Activity Nr Safety Health
Accident 362062747
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 1 1 2
Initial Penalty $24,300 $0 $0 $0 $0 $24,300
Current Penalty $3,710 $0 $0 $685 $0 $4,395
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 1541 H01 02/28/2001 03/05/2001 $685 $14,400 $0 I - Informal Settlement  
2. 02001 Serious 15410001 C01 A 02/28/2001 03/05/2001 $3,710 $4,950 $0 I - Informal Settlement  
3. 03001 Serious 1541 K01 02/28/2001 03/10/2001 $0 $4,950 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 201063559
Event: 10/24/2000
Employee Injured When Buried In Excavation

The company was on-site to conduct sewer repairs at a depth of approximately 14 ft. The job was in an alley between rows of homes in a residential area. Employee #1 was inside the excavation fine grading. The employer had hydraulic speed shores and 4-ft by 8-ft sheets of wood backing every 4 ft to 5 ft apart for shoring. The excavation had water accumulation from the sewer laterals that came from the homes nearby. The sewer laterals had not been plugged or shut off, so when someone flushed their toilet, used the water or laundry; the water would flow into the excavation. While Employee #1 was inside the excavation the water caused the unshored areas of the excavation (the areas between the plywood backing, and the area below the plywood backing) to erode. This in turn caused the shored areas to become undermined and twist and collapse. Employee #1was buried by the sand and sewage water until the fire department saved him. Employee #1 suffered circulation problems from the sand compressing his body for a long period of time. Employee #1 was hospitalized for five days for circulatory treatment.

Keywords: SEWER, EXCAVATION, REPAIR, SHORING, WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300785037 Hospitalized injury Other Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.