Powered by GoogleTranslate

Inspection Detail

Inspection: 300778826 - Tomco Auto Products Inc

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 300778826
Report ID: 0950642
Date Opened: 02/15/2002

Site Address:
Tomco Auto Products Inc
4330 East 26th Street
Vernon, CA 90058

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:7539

NAICS: 811118/Other Automotive Mechanical and Electrical Repair and Maintenance


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/27/2002

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 09/16/2002


Related Activity
Type Activity Nr Safety Health
Accident 101051084
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 6 7
Current Violations 1 6 7
Initial Penalty $4,500 $0 $0 $2,245 $0 $6,745
Current Penalty $2,700 $0 $0 $1,650 $0 $4,350
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 06/28/2002 07/31/2002 $300 $375 $0 I - Informal Settlement  
2. 01002 Other 461 A 06/28/2002 07/31/2002 $300 $375 $0 I - Informal Settlement  
3. 01003 Other 23400016 B 06/28/2002 07/31/2002 $150 $375 $0 I - Informal Settlement  
4. 01004 Other 23400021 06/28/2002 07/31/2002 $150 $185 $0 I - Informal Settlement  
5. 01005 Other 3203 A 06/28/2002 07/31/2002 $150 $185 $0 I - Informal Settlement  
6. 01006 Other 3328 E 06/28/2002 08/30/2002 $600 $750 $0 I - Informal Settlement  
7. 02001 Serious 23400023 06/28/2002 07/11/2002 $2,700 $4,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 201056314
Event: 01/17/2002
Employee Burned From Hot Water

At approximately 9:30 a.m. on January 17, 2002, Employee #1, a 16-year veteran shop supervisor with Tomco Auto Products, was in the cleaning department of Tomco Auto parts near the Roto-Jet model number 5 washing machine. This machine was used to clean carburetors with a 30/1 detergent (Powerblast) and water solution that was heated between 150 and 200 degrees Fahrenheit. Because the machine had been turned off approximately 3 hours before the accident, a precise temperature of the water could not be determined. The machine had to be cleaned and Employee #1 direct supervisor and coworkers were in the process of pumping the detergent solution out by removing a pipe elbow at the filter housing and connecting a 1.25-inch-inner-diameter rubber hose to the pipe so that the liquid could be transferred to other containers. The hose was fastened to the pipe with a screw clamp and run through a hole in a nearby wall in order to reach the containers. When one of the containers was almost full, the valve was turned off so that the containers could be switched. Both coworkers proceeded to switch the containers after which it was necessary to turn the valve back on. On coworker instructed the other to hold the hose at the container end and he would turn the valve back on. Overhearing that the valve needed to be turned on, Employee #1 offered to do it since he was headed in that direction. Employee #1 was not assigned to help clean the machine and had not done so in the past apart from past supervision of its cleaning. After turning the valve on, both coworkers told him that nothing was coming out so Employee #1 turned to see the end of the hose from where the solution was supposed to be flowing. Approximately 30 seconds later, the hose became detached from the pipe, spraying Employee #1 with the hot water and detergent solution. After the accident occurred, one coworker discovered that the hose had become kinked at the point where it was run through the wall. Employee #1 was initially taken to US Healthworks. He was subsequently transferred to an East Los Angeles hospital and finally to Grossman Burn Center in the Sherman Oaks Hospital Sherman Oaks, California, where he remained for 22 days and was treated for first-, second-, and third-degree burns over 12 percent of his lower legs. The accident was caused by the rubber hose connected to the filter housing pipe was not adequately secured to prevent it from disengaging. Furthermore, the hose became kinked, increasing pressure in the hose. None of the employees involved was aware that the hose had become kinked.

Keywords: BURN, CLEANING, HOSE, LOCKOUT, PRESSURE RELEASE, HIGH TEMPERATURE, HOT WATER, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300778826 Hospitalized injury Burn/Scald(Heat) Supervisors; handlers,equip-cleaners,laborers nec
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close