Powered by GoogleTranslate

Inspection Detail

Inspection: 300649084 - Fab Tec, Inc.

Inspection Information - Office: Savannah Area Office

 

Inspection Nr: 300649084
Report ID: 0418400
Date Opened: 10/06/1998

Site Address:
Fab Tec, Inc.
8362 Bowens Mill Rd.
Broxton, GA 31519

Mailing Address:
2150 Industrial Blvd., Douglas, GA 31533

Union Status: NonUnion

SIC:3441

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 03/19/1999

Planning Guide: Safety-Manufacturing

Emphasis: S:Construction, S:Construction Fatalities

Case Closed: 02/03/2000


Related Activity
Type Activity Nr Safety Health
Accident 100900638
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 3 1 4
Initial Penalty $13,000 $0 $0 $0 $0 $13,000
Current Penalty $5,500 $0 $0 $1,000 $0 $6,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 03/19/1999 05/05/1999 $3,500 $5,000 $0 04/13/1999 F - Formal Settlement  
2. 01002A Serious 19260050 B 03/19/1999 05/05/1999 $1,000 $1,500 $0 04/13/1999 F - Formal Settlement  
3. 01002B Serious 19260050 E 03/19/1999 05/05/1999 $0 $0 $0 04/13/1999 F - Formal Settlement  
4. 01003 Other 19260404 F03 IID 03/19/1999 03/24/1999 $1,000 $5,000 $0 04/13/1999 F - Formal Settlement  
5. 01004 Serious 19260501 B01 03/19/1999 03/24/1999 $1,000 $1,500 $0 04/13/1999 F - Formal Settlement  

Investigation Summary

Investigation Nr: 200900470
Event: 09/25/1998
electric shock - ground fault in electric generator

Two employees were going to install two canopies at a new construction site. One of the employees was standing on the top platform of the truck with an electric generator running in the idle position. He was waiting for his coworker to pass up steel struts to be welded. The coworker opened the passenger door on the truck and reached under the seat, looking for a glass for a drink of water. Standing on the ground, he leaned into the truck with his lower legs touching the truck. He received an electric shock, which knocked him about 1.5 meters away from the truck. The first employee also received an electric shock and fell from the top platform to a lower deck over the hood. He was transported to a local hospital, where he was admitted and placed on life support. Six days later, the family requested that the life support be removed, and he was pronounced dead of electrocution. The generator, which was not properly grounded, had an apparent ground fault.

Keywords: ELECTRICAL, ELECTROCUTED, E C, GROUND FAULT, EQUIPMENT GROUNDING, ELECTRIC GENERATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300649084 Fatality Electric Shock Occupation not reported
2 300649084 Non Hospitalized injury Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close