Powered by GoogleTranslate

Inspection Detail

Inspection: 300648854 - Langdale Forest Products Company

Inspection Information - Office: Savannah Area Office

 

Inspection Nr: 300648854
Report ID: 0418400
Date Opened: 08/27/1998

Site Address:
Langdale Forest Products Company
1202 Madison Hwy
Valdosta, GA 31601

Mailing Address:
P. O. Box 1088, Valdosta, GA 31603

Union Status: NonUnion

SIC:1629

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 01/08/1999

Emphasis:

Case Closed: 09/08/1999


Related Activity
Type Activity Nr Safety Health
Accident 100900596
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 7 7
Current Violations 6 6
Initial Penalty $35,000 $0 $0 $0 $0 $35,000
Current Penalty $18,000 $0 $0 $0 $0 $18,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260021 B02 01/08/1999 01/13/1999 $5,000 $5,000 $0 -  
2. 01001B Serious 19260020 B02 01/08/1999 01/13/1999 $0 $0 $0 -  
3. 01002 Serious 19260095 A 01/08/1999 01/13/1999 $0 $5,000 $0 I - Informal Settlement  
4. 01003 Serious 19260403 B01 01/08/1999 01/13/1999 $0 $5,000 $0 I - Informal Settlement Citation has been deleted.
5. 01004A Serious 19260416 A01 01/08/1999 01/13/1999 $5,000 $5,000 $0 -  
6. 01004B Serious 19260403 I02 I 01/08/1999 01/13/1999 $0 $0 $0 -  
7. 01004C Serious 19260403 H 01/08/1999 01/13/1999 $0 $0 $0 I - Informal Settlement Citation has been deleted.
8. 01004D Serious 19260417 C 01/08/1999 01/13/1999 $0 $0 $0 -  
9. 01005 Serious 19260501 B01 01/08/1999 01/19/1999 $3,000 $5,000 $0 I - Informal Settlement  
10. 01006 Serious 19261053 B12 01/08/1999 01/19/1999 $0 $5,000 $0 I - Informal Settlement  
11. 01007A Serious 19261060 A 01/08/1999 01/19/1999 $5,000 $5,000 $0 -  
12. 01007B Serious 19261053 B01 01/08/1999 01/19/1999 $0 $0 $0 -  
13. 01007C Serious 19261053 B07 01/08/1999 01/19/1999 $0 $0 $0 -  
14. 01007D Serious 19261053 B22 01/08/1999 01/19/1999 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 200900413
Event: 08/26/1998
electric shock - direct contact with energized parts

An electrician placed his upper torso in an electrical cabinet into which a 480-volt, three-phase circuit breaker was going to be installed. The employee contacted energized parts in the cabinet and was electrocuted.

Keywords: E GI IV, ELECTRICAL, ELECTRICIAN, ELECTROCUTED, ELECTRICAL WORK, LOCKOUT, CIRCUIT BREAKER, ELECTRICAL CABINET

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300648854 Fatality Electric Shock Electricians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close