Powered by GoogleTranslate

Inspection Detail

Inspection: 300494002 - Metro Air Services, Inc.

Inspection Information - Office: Fort Lauderdale Area Office

 

Inspection Nr: 300494002
Report ID: 0418800
Date Opened: 07/23/1997

Site Address:
Metro Air Services, Inc.
961 Ne 96th Street
Miami Shores, FL 33138

Mailing Address:
8136 Nw 67 Street, Miami, FL 33166

Union Status: NonUnion

SIC:7623

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/31/1997

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 09/01/1998


Related Activity
Type Activity Nr Safety Health
Accident 361078223
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 4 1 5
Initial Penalty $4,800 $0 $0 $0 $0 $4,800
Current Penalty $3,600 $0 $0 $0 $0 $3,600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260020 B01 01/06/1998 01/16/1998 $1,500 $1,500 $0 -  
2. 01002 Serious 19260404 B01 I 01/06/1998 01/12/1998 $300 $600 $0 I - Informal Settlement  
3. 01003 Other 19260404 F06 01/06/1998 01/09/1998 $0 $600 $0 I - Informal Settlement  
4. 01004 Serious 19260416 A03 01/06/1998 01/09/1998 $1,500 $1,500 $0 -  
5. 01005 Serious 19260416 E01 01/06/1998 01/12/1998 $300 $600 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200670834
Event: 07/22/1997
electric shock - direct contact with energized parts

An employee was working in the attic crawlspace of a residence, replacing an existing air-conditioning unit. After connecting the new unit to the wiring, the employee came down from the attic into the residence to energize the unit. When he returned to the attic, the employee contacted an energized part while he was touching either the 13-millimeter-diameter electric metallic tubing or the nearby ceiling-mounted electric fan. The employee was electrocuted.

Keywords: E GI IV, ELECTRICAL, AIR CONDITIONER, ELECTROCUTED, ELECTRICAL WORK, LOCKOUT, ELEC CIRC PART--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300494002 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.