Powered by GoogleTranslate

Inspection Detail

Inspection: 300476215 - Chief Supply Corp.

Inspection Information - Office: Oklahoma City Area Office

 

Inspection Nr: 300476215
Report ID: 0627700
Date Opened: 03/27/1997

Site Address:
Chief Supply Corp.
7637 N.W. 3rd
Oklahoma City, OK 73127

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:4953

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 06/13/1997

Emphasis: L:Hazwaste

Case Closed: 03/04/2008


Related Activity
Type Activity Nr Safety Health
Accident 100640531
Referral 200640399 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 2 3 1 12
Current Violations 6 2 3 1 12
Initial Penalty $30,000 $140,000 $150,000 $0 $0 $320,000
Current Penalty $30,000 $140,000 $150,000 $0 $0 $320,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100120 P01 09/24/1997 10/27/1997 $5,000 $5,000 $0 10/09/1997 F - Formal Settlement  
2. 01002A Serious 19100120 P07 I 09/24/1997 10/27/1997 $5,000 $5,000 $0 10/09/1997 F - Formal Settlement  
3. 01002B Serious 19100120 P07 II 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
4. 01003A Serious 19100134 B01 09/24/1997 10/27/1997 $5,000 $5,000 $0 10/09/1997 F - Formal Settlement  
5. 01003B Serious 19100134 B03 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
6. 01003C Serious 19100134 B10 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
7. 01003D Serious 19100134 E05 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
8. 01004A Serious 19100134 B05 09/24/1997 10/11/1997 $5,000 $5,000 $0 10/09/1997 F - Formal Settlement  
9. 01004B Serious 19100134 B06 09/24/1997 10/04/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
10. 01004C Serious 19100134 B07 09/24/1997 10/11/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
11. 01005 Serious 19100134 B08 09/24/1997 10/27/1997 $5,000 $5,000 $0 10/09/1997 F - Formal Settlement  
12. 01006A Serious 19101200 F05 I 09/24/1997 10/11/1997 $5,000 $5,000 $0 10/09/1997 F - Formal Settlement  
13. 01006B Serious 19101200 F05 II 09/24/1997 10/11/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
14. 01006C Serious 19101200 H01 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
15. 01006D Serious 19101200 H03 II 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
16. 02001A Willful 19100120 P08 IIIA 09/24/1997 10/27/1997 $70,000 $70,000 $0 10/09/1997 F - Formal Settlement  
17. 02001B Willful 19100120 P08 IIIB 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
18. 02001C Willful 19100120 P08 IIIC 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
19. 02001D Willful 19100120 P08 IVB 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
20. 02001E Willful 19100120 P08 IVC 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
21. 02001F Willful 19100120 P08 IVD 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
22. 02001G Willful 19100120 P08 IVE 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
23. 02002 Willful 19100151 C 09/24/1997 10/27/1997 $70,000 $70,000 $0 10/09/1997 F - Formal Settlement  
24. 03001 Repeat 19100120 P03 09/24/1997 10/27/1997 $50,000 $50,000 $0 10/09/1997 F - Formal Settlement  
25. 03002 Repeat 19100120 P04 09/24/1997 10/27/1997 $50,000 $50,000 $0 10/09/1997 F - Formal Settlement  
26. 03003A Repeat 19100120 P08 I 09/24/1997 10/27/1997 $50,000 $50,000 $0 10/09/1997 F - Formal Settlement  
27. 03003B Repeat 19100120 P08 IIA 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
28. 03003C Repeat 19100120 P08 IIB 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
29. 03003D Repeat 19100120 P08 IIC 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
30. 03003E Repeat 19100120 P08 IID 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
31. 03003F Repeat 19100120 P08 IIE 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
32. 03003G Repeat 19100120 P08 IIF 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
33. 03003H Repeat 19100120 P08 IIG 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
34. 03003I Repeat 19100120 P08 IIH 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
35. 03003J Repeat 19100120 P08 III 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
36. 03003K Repeat 19100120 P08 IIJ 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
37. 03003L Repeat 19100120 P08 IIK 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  
38. 04001 Other 19100120 P05 09/24/1997 10/27/1997 $0 $0 $0 10/09/1997 F - Formal Settlement  

Investigation Summary

Investigation Nr: 200640266
Event: 03/26/1997
Two employees burned in explosion and fire

Employees #1 and #2, both production workers, were part of a team that was blending flammable organic solvent-based waste into waste kiln fuel. Production was up because a shipment needed to be transported soon, and Employees #1 and #2 were dumping drums of waste into blending dispersers. After emptying a previous batch out of the small disperser, its mixer wheel stopped running, so a lab worker, following a recently reinstated practice, poured approximately one gallon each of dry chlorates and perchlorates into the disperser's interior. The lab worker then went back to the laboratory and returned with a gallon of dry nitrites, which he also poured into the container. Employees #1 and #2 had, by this time, both moved on to new projects. Employee #2 was operating a forklift with an attached drum dumping fixture; Employee #1 was standing on the fixture, starting to dump another drum. The lab worker conversed briefly with Employee #2 and was starting to walk away when waste erupted from the top of the dispenser, followed by a large fireball. Both Employees #1 and #2 were sprayed by the burning waste; Employee #1's Tyvek suit caught fire, as did Employee #2's shirt collar. Some coworkers tried to help them, while others began fighting the flames before all the workers were evacuated. Employee #1 died of burns sustained in the accident; Employee #2 suffered burns to his neck but was not hospitalized. The fire ultimately destroyed the entire upper level of the plant. Its probable cause was the addition of the three different oxidizers to the flammable organic solvent-based waste. The three oxidizers reacted among themselves, and with the waste liquid, producing intense heat that ignited the waste's flammable vapors.

Keywords: FLAMMABLE VAPORS, WORK RULES, WASTE PROC FAC, EXPLOSION, BURN, HEAT, MIXER, CHEMICAL REACTION, MECH MALFUNCTION, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300476215 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close