Powered by GoogleTranslate

Inspection Detail

Inspection: 300445129 - Webster Valve Co.

Inspection Information - Office: Concord Area Office

 

Inspection Nr: 300445129
Report ID: 0111700
Date Opened: 12/15/1997

Site Address:
Webster Valve Co.
So. Main St.
Franklin, NH 03235

Mailing Address:
Po Box 431, Franklin, NH 03235

Union Status: NonUnion

SIC:3491

NAICS: 0 


Inspection Type: Complaint

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/05/1998

Emphasis:

Case Closed: 03/05/1998


Related Activity
Type Activity Nr Safety Health
Complaint 200606648 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $1,875 $0 $0 $0 $0 $1,875
Current Penalty $1,875 $0 $0 $0 $0 $1,875
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 5A0001 02/02/1998 03/09/1998 $1,875 $1,875 $0 -  
2. 01001B Serious 19100307 B 02/02/1998 03/09/1998 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 200611234
Event: 12/05/1997
Employee troubleshooting propane unit injured in explosion

Two employees were servicing an Aerovent makeup-air unit, which contained a buildup of propane gas because of a malfunctioning valve. Normally, the valve, a relief device, vented the propane gas to the exterior of the unit or another safe location. While the employees were troubleshooting, an electric arc in the wiring ignited the propane atmosphere and caused an explosion. The electrical wiring installation was not suitable for use in the hazardous location. One employee, who was injured in the explosion, was hospitalized.

Keywords: ELECTRIC ARC, MAINTENANCE, E GI IV, ELECTRICAL, VENTILATION, EXPLOSION, HEAT EXCHANGER, ELECTRIC CONDUCTOR, PROPANE, EQUIPMENT APPROVAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300445129 Hospitalized injury Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.