Powered by GoogleTranslate

Inspection Detail

Inspection: 300239688 - General Irrigation, Inc.

Inspection Information - Office: Bismarck Area Office

 

Inspection Nr: 300239688
Report ID: 0830300
Date Opened: 07/19/1999

Site Address:
General Irrigation, Inc.
Four Miles South & 1/2 Mile East
Oakes, ND 58474

Mailing Address:
Box 291, Oakes, ND 58474

Union Status: NonUnion

SIC:5083

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 07/19/1999

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 12/17/1999


Related Activity
Type Activity Nr Safety Health
Accident 100330448
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $1,500 $0 $0 $0 $0 $1,500
Current Penalty $1,500 $0 $0 $0 $0 $1,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100333 A01 08/10/1999 09/13/1999 $1,500 $1,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200330405
Event: 07/17/1999
ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED PARTS

An employee of an irrigation system supply company, assisted by an employee of a landowner, was repairing an irrigation system's main pipe. The pipe had broken when it caught on a tree limb. The employees had to remove an electric cable from a control box mounted at the top of a support tower so that they could get to the pipe. However, they had not deenergized the 480-volt equipment. The irrigation supply worker was standing on a steel support member of the tower and had disconnected four or five conductors in the control box. As he was removing the cable from the bottom of the box, he contacted energized parts in the top section of the equipment. The helper, who had been retrieving tools at the time of the accident, saw that the victim was on the tower, unable to let go. The helper went to open the disconnecting means at the main panel, which was located about 0.4 kilometers away. When the helper was about 100 meters from the tower, he looked back and saw that the victim had fallen off the tower. The helper returned to the tower and found the victim lying on the ground with no pulse or respiration. Emergency medical services transported the victim to a hospital, where he was pronounced dead on arrival. He had been electrocuted. The irrigation employee had 15 years of experience in installing, maintaining, and repairing center-pivot irrigation systems and had received factory training on the systems for 8 consecutive years. His training included instruction in electrical systems.

Keywords: E GI IV, ELECTRICAL, ELECTRIC CABLE, ELECTROCUTED, ELECTRICAL WORK, LOCKOUT, ELEC CIRC PART--MISC, ELECTRICAL BOX

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300239688 Fatality Electric Shock Farm equipment mechanics
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close