Powered by GoogleTranslate

Inspection Detail

Inspection: 2934677 - Southern California Edison

Inspection Information - Office: Nv-E-Las Vegas 0953220

 

Inspection Nr: 2934677
Report ID: 0953220
Date Opened: 06/10/1985

Site Address:
Southern California Edison
Edison Way
Laughlin, NV 89046

Mailing Address:
Po Box 505, Laughlin, NV 89046

Union Status: Union

SIC:4911

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 06/13/1985

Emphasis:

Case Closed: 06/21/1985


Related Activity
Type Activity Nr Safety Health
Accident 36063782

Investigation Summary

Investigation Nr: 14236061
Event: 06/09/1985
HIGH-PRESSURE STEAM PIPE RUPTURED

A 762-millimeter-diameter steam pipe in an electric power generation plant ruptured. The welded steam pipe apparently failed at the welded seam and split longitudinally along the 4.9-meter length of the pipe. The pipe contained reheated steam at 2000 to 2300 pascals and 538 degrees Celsius. When the pipe ruptured, it vented toward the lunch and control rooms, subjecting 16 employees to the steam and flying debris. The blast entered the areas through an open door in the lunchroom and through the glass of a closed door in the control room, killing six of the employees and injuring the rest. The injured and deceased employees were located in these two rooms. Traffic was heavier in these areas at the time of the blast because it was time for a shift change and employees were picking up their assignments to start the second shift. The ten employees who survived the blast were hospitalized for their injuries.

Keywords: STEAM, PIPE, BURN, RUPTURE, HIGH PRESSURE, ELEC UTILITY WORK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 2934677 Fatality Burn/Scald(Heat) Occupation not reported
2 2934677 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 2934677 Hospitalized injury Burn/Scald(Heat) Occupation not reported
4 2934677 Fatality Burn/Scald(Heat) Occupation not reported
5 2934677 Fatality Burn/Scald(Heat) Occupation not reported
6 2934677 Hospitalized injury Burn/Scald(Heat) Occupation not reported
7 2934677 Hospitalized injury Burn/Scald(Heat) Occupation not reported
8 2934677 Fatality Burn/Scald(Heat) Occupation not reported
9 2934677 Hospitalized injury Burn/Scald(Heat) Occupation not reported
10 2934677 Fatality Burn/Scald(Heat) Occupation not reported
11 2934677 Hospitalized injury Burn/Scald(Heat) Occupation not reported
12 2934677 Hospitalized injury Burn/Scald(Heat) Occupation not reported
13 2934677 Fatality Burn/Scald(Heat) Occupation not reported
14 2934677 Hospitalized injury Burn/Scald(Heat) Occupation not reported
15 2934677 Hospitalized injury Burn/Scald(Heat) Occupation not reported
16 2934677 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close