Powered by GoogleTranslate

Inspection Detail

Inspection: 2837276 - Campbell Soup Company

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 2837276
Report ID: 0352410
Date Opened: 06/12/1986

Site Address:
Campbell Soup Company
P.O. Bo 1618 West Road
Salisbury, MD 21801

Mailing Address:
Campbell Place, Camden, NJ 08101

Union Status: Union

SIC:2038

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/30/1986

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 08/18/1986


Related Activity
Type Activity Nr Safety Health
Accident 360747174
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $570 $0 $0 $0 $0 $570
Current Penalty $380 $0 $0 $0 $0 $380
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 890032 A 07/24/1986 07/27/1986 $380 $570 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 14198675
Event: 05/31/1986
EMPLOYEE'S FINGER AMPUTATED BY AUGER BLADES OF MIXER

EMPLOYEE #1 WAS CLEANING A MEPACO #170 VEGETABLE MIXING MACHINE, SERIAL #382, WHEN THE ACCIDENT OCCURRED. THE VEGETABLE MIXER IS EQUIPPED WITH TWIN AUGER BLADES. IT IS CLEANED ON A DAILY BASIS BY MEMBERS OF THE THIRD SHIFT. A STREAM OF WATER UNDER HIGH PRESSURE IS USED TO CLEAN THE MIXER. HE HAD STARTED THE AUGERS SO THEY WOULD SWEEP WATER AND VEGETABLES OUT THE DISCHARGE DOORS AND ONTO THE FLOOR. HE NOTICED A BUILD UP OF RICE ON THE LIP OF THE LEFT DISCHARGE DOOR. HE AIMED A STREAM OF WATER DIRECTLY AT THE BUILD UP. HOWEVER, THERE WAS INSUFFICIENT WATER PRESSURE TO REMOVE THE RICE FROM HIS POSITION AT THE REAR OF THE MIXER. WITH THE AUGER BLADES RUNNING, THE EMPLOYEE WALKED TO THE DISCHARGE END OF THE EQUIPMENT. HE SQUATTED DOWN, REACHED UP UNDER THE BARRIER GUARD AND AIMED THE STREAM OF WATER AT THE LIP OF THE 12 INCH DIAMETER DOOR. FROM HIS POSITION, HE HAD TO PLACE HIS HAND VERY CLOSE TO THE DOOR OPENING TO BE ABLE TO EFFECTIVELY STRIKE THE RICE BUILD UP WITH THE STREAM OF WATER. HE CAME TOO CLOSE TO THE AUGER BLADE AND WAS STRUCK BY IT. THE BLADE SEVERED HIS RIGHT INDEX FINGER AND LACERATED HIS RIGHT THUMB. THERE WERE NO WRITTEN WORK RULES REGARDING THE SAFE PROCEDURE FOR CLEANING THIS EQUIPMENT.

Keywords: MIXER BLADE, AMPUTATED, FINGER, WORK RULES, CLEANING, LACERATION, AUGER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 2837276 Hospitalized injury Amputation Supervisors; handlers,equip-cleaners,laborers nec
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.